Function Settings and Operations
4-15
4.12 Distance Adjustment
This function corrects any deviation in the length of cut or the plotted line segments, which occurs depending
on the medium being used. The adjustment value for the deviation is specified as a percentage of the total
distance. For example, a setting of 0.05% adjusts a distance of 2 m (2,000 mm) by +1 mm (2000 x 0.05% = 1
mm), to become 2,001 mm. Eight different cutter-pen condition-setting areas can be set on or off separately,
allowing different settings to be made in order to suit the medium used.
(1) Press the
(PAUSE) key to switch to PAUSE mode.
(2) Press the
(NEXT) or
(PREV.) key until the following menu is displayed.
A D V A N C E D F U N C .
(3) Press the
(ENTER) key, and then press the
(NEXT) or
(PREV.) key
until the following menu is displayed.
D I S T A N C E A D J U S T
(4) Press the
(ENTER) key to display the distance adjustment menu. The
numbers "1" to "8" indicate the cutter-pen condition-setting areas, and those that
are set on are indicated with the
s
symbol to the left.
1 2 3 4 5 6 7 8
Use the
or
key to move the cursor to select the required condition-
setting area. Press the
or
key to display or not display the
s
symbol,
and then press the
(ENTER) key to confirm. To cancel, press the
(NEXT) or
(PREV.) key.
(5) Press the
(PAUSE) key to cancel PAUSE mode.
(6) Select the condition-setting area to be set to "ON" (refer to "Selecting Cutter-Pen-
Condition Setting Areas" on page 3-6).
5 1 5 U 0 2 0 3 0 1
(7) Either press the
(ENTER) key or use the
key to move the cursor to the far
right, and then press the
key to display the following menu.
X = 0 . 0 0 % Y = 0 . 0 0 %
(8) Select "X" or "Y" using the
or
key. Use the
or
key to increase or
decrease the setting within the range of "-2.00%" to "+2.00%," and then press
the
(ENTER) key to confirm. If the condition-setting area is set for
TANGENTIAL mode, the TANGENTIAL-mode setting will be displayed. Press
(ENTER) again. To cancel the selection(s), press the
(NEXT) or
(PREV.)
key.
CHECKPOINT
This setting is retained in the memory even when the power is turned off.
B L A D E W A R E S E T U P
C U T L I N E P A T .
T A N G E N T I A L
I N I T . B
P E N U P S P E E D
I N I T I A L F E E D
A U T O P R E F E E D
S E T U P M E N U
T E S T
F E E D & C U T
P E N U P / D O W N
A D V A N C E D F U N C .
C L E A R B U F F E R