P a g e
|
147
UCM6510 IP PBX User Manual
Version 1.0.20.31
CC Max Agents
Configure the maximum number of CCSS agents which may be allocated
for this channel
(when CC Mode is set to “For Trunk”). In other words, this
number serves as the maximum number of CC requests this channel is
allowed to make. Min. value is 1.
CC Max Monitors
Configure the maximum number of monitor structures which may be
created for this device
(when CC Mode is set to “For Trunk”). This number
tells how many callers may request CC services for a specific device at
one time. The minimum value is 1.
Ring Simultaneously
Ring Simultaneously
Enable this option to have an external number ring simultaneously along
with the extension. If a register trunk is used for outbound, the register
number will be used to be displayed for the external number as caller ID
number.
External Number
Set the external number to be rang simultaneously. ‘-’ is the connection
character which will be ignored.
This field accepts only letters, numbers, and special char = * #.
Time Condition for Ring
Simultaneously
Ring the external number simultaneously along with the extension based
on this time condition.
Use callee DOD on FWD or
Ring Simultaneously
Use the DOD number when calls are being diverted/forwarded to external
destinations or when ring simultaneous is configured.
Monitor privilege control
Allow call-barging
Add members from “Available Extensions” to “Selected Extensions” so
that the selected extensions can spy on the used extension using feature
code.
Seamless transfer privilege control
Allowed to seamless transfer
Any extensions on the UCM can perform seamless transfer. When using
Pickup Incall feature, only e
xtensions available on the “Selected
Extensions” list can perform seamless transfer to the edited extension.
Other Settings
Ring Timeout
Configure the number of seconds to ring the user before the call is
forwarded to voicemail (voicemail is enabled) or hang up (voicemail is
disabled). If not specified, the default ring timeout is 60 seconds on the
UCM6510, which can be configured in the global ring timeout setting under
Web GUI
PBX Settings
General Settings
: General Preference. The
valid range is between 5 seconds and 600 seconds.
Note
:
If the end point also has a ring timeout configured, the actual ring timeout
used is the shortest time set by either device.
Содержание UCM6510
Страница 1: ...Grandstream Networks Inc UCM6510 IP PBX User Manual ...
Страница 45: ...P a g e 44 UCM6510 IP PBX User Manual Version 1 0 20 31 Firmware Version 1 0 0 25 This is the initial version ...
Страница 83: ...P a g e 82 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 28 Fail2ban Settings ...
Страница 137: ...P a g e 136 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 79 Zero Config Sample Global Policy ...
Страница 273: ...P a g e 272 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 163 Black White List ...
Страница 327: ...P a g e 326 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 213 Fax Sending in Web GUI ...
Страница 331: ...P a g e 330 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 216 Presence Status CDR ...
Страница 470: ...P a g e 469 UCM6510 IP PBX User Manual Version 1 0 20 31 Figure 334 Cleaner ...