P a g e
|
136
GWN7000 User Manual
Version 1.0.6.28
MAINTENANCE AND TROUBLESHOOTING
GWN7000 offers multiple tools and options for maintenance and debugging to help further troubleshooting
and monitoring the GWN7000 resources.
Maintenance
Maintenance page can be accessed from GWN7000 WebGUI
→
System Settings
→
Maintenance
.
Maintenance page includes different tabs: Basic, Upgrade, Access, Syslog and Logserver.
Basic
Table 45: Maintenance - Basic
Rebind Protection
Anti-domain name hijacking protection.
If enabled, when the address returned by the superior DNS is a private LAN
address, it will be regarded as a domain name hijacking, thus discarding the
analytical result.
If disabled, the analytical result will not be discarded.
Web WAN Access
Enable the web WAN access. By default, it’s disabled
Web HTTP Access
Enable the web HTTP Access. By default, it’s disabled.
Web HTTPS Port
Specifies the HTTPS port. By default, is 443.
Country
Select the country from the drop-down list.
Time Zone
Configure time zone for the GWN7000.
Please reboot the device to take effect.
NTP Server
Configure the IP address or URL of the NTP server, the device will obtain the
date and time from the configured server.
Date Display Format
Change the Date Display Format, three options are possible YYYY/MM/DD,
MM/DD/YYYY and DD/MM/YYYY
Upgrade
Table 46: Maintenance - Upgrade
Authenticate Config File
Authenticate configuration file before acceptance. Default is disabled.
XML Config File Password
Enter the password for encrypting the XML configuration file using OpenSSL.
The password is used to decrypt the XML configuration file if it is encrypted.
Upgrade Via
Specify uploading method for firmware and configuration. 3 options are
available: HTTP, HTTPS and TFTP.