SWD1013N_SVG
Figure 21
Connect the Washer to Electrical Power
This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.
Washer Electrical Requirements
400 Volt, 50 Hertz, 9.8 Amp
NOTE: This washer is factory-wired for a 400 Volt elec-
trical supply.
NOTE: The wiring diagram is located in the control cab-
inet.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST abide with local electrical codes.
It is the customer’s responsibility to have the wiring,
fuses and circuit breakers installed by a qualified
electrician to make sure adequate electrical power is
available to the washer.
W882
When connecting the washer to electrical power:
• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate both a washer and a gas dryer on the same
circuit.
Machine Must Be Hard Wired
SWD1034N_SVG
NOTE: Electrical disconnect must be located so that
it is easily accessible with machine in place. Ma-
chine must be hard wired. An intermediate shut-off
box that provides all pole disconnection from the
supply mains must be used in compliance with all
local electrical codes.
Figure 22
Earth/Ground Instructions
This appliance must be properly connected to protective earth/
ground. In the event of malfunction or breakdown, the earth/
ground will reduce the risk of electric shock by providing a path
of least resistance for electric current.
The washer must be hard wired into an appropriate power source
that is properly installed and connected to a protective earth/
ground in accordance with all local codes and ordinances.