background image

SWD1013N_SVG

Figure 21

 Connect the Washer to Electrical Power

This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.

 Washer Electrical Requirements

400 Volt, 50 Hertz, 9.8 Amp

NOTE: This washer is factory-wired for a 400 Volt elec-
trical supply.

NOTE: The wiring diagram is located in the control cab-
inet.

WARNING

To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST abide with local electrical codes.
It is the customer’s responsibility to have the wiring,
fuses and circuit breakers installed by a qualified
electrician to make sure adequate electrical power is
available to the washer.

W882

When connecting the washer to electrical power:

• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate both a washer and a gas dryer on the same

circuit.

Machine Must Be Hard Wired

SWD1034N_SVG

NOTE: Electrical disconnect must be located so that
it is easily accessible with machine in place. Ma-
chine must be hard wired. An intermediate shut-off
box that provides all pole disconnection from the
supply mains must be used in compliance with all
local electrical codes.

Figure 22

 Earth/Ground Instructions

This appliance must be properly connected to protective earth/
ground. In the event of malfunction or breakdown, the earth/
ground will reduce the risk of electric shock by providing a path
of least resistance for electric current.

The washer must be hard wired into an appropriate power source
that is properly installed and connected to a protective earth/
ground in accordance with all local codes and ordinances.

Installation

©

 Published by permission of the copyright owner -

 DO NOT COPY or TRANSMIT

  28

  Part No. 805898ENR1

Содержание 805898ENR1

Страница 1: ...acked Washer Dryers Electric and Gas Models SWD455C_SVG Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine Part No...

Страница 2: ......

Страница 3: ...mells gas The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use WARNING Installation of unit must be perfo...

Страница 4: ...s Supply Pipe 20 Connect Dryer Exhaust System 22 Exhaust Direction 23 Exhaust System 23 Multi Dryer Installation Exhaust Requirements 24 Position and Level the Unit 26 Wipe Out Inside of Washer and Dr...

Страница 5: ...termine Proper Controls 35 Set Fabric Selector 35 Insert Coins if Needed 35 Start Dryer 36 Remove Laundry 36 Indicator Lights 36 Maintenance 37 User Maintenance Instructions 37 Lubrication 37 Cold Wea...

Страница 6: ...asher where it will be exposed to water and or weather Do not add the following substances or textiles containing traces of the following substances to the wash water gasoline kerosene waxes cooking o...

Страница 7: ...ns when using your dryer fol low these basic precautions W130 Read all instructions before using the dryer Install this dryer according to the INSTALLATION IN STRUCTIONS Refer to the EARTH GROUND INST...

Страница 8: ...duct should be cleaned periodically by qualified service personnel Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in the user main tenance ins...

Страница 9: ...8 375 in E 610 mm 24 in F 203 mm 8 in G 391 mm 15 4 in H 938 mm 36 9 in I 368 mm 14 5 in J 813 mm 32 in K 683 mm 26 875 in L 1986 mm 78 17 in M 1184 mm 46 62 in N 52 mm 2 04 in O 704 mm 27 73 in P 38...

Страница 10: ...G 391 mm 15 4 in H 59 mm 2 3 in I 938 mm 36 9 in J 368 mm 14 5 in K 1140 mm 44 87 in L 813 mm 32 in M 683 mm 26 875 in N 1986 mm 78 17 in O 1184 mm 46 62 in P 52 mm 2 04 in Q 704 mm 27 73 in R 38 mm...

Страница 11: ...mm 24 in F 203 mm 8 in G 391 mm 15 4 in H 938 mm 36 9 in I 368 mm 14 5 in J 813 mm 32 in K 683 mm 26 875 in L 107 mm 4 2 in M 104 mm 4 1 in N 1184 mm 46 62 in O 1986 mm 78 17 in P 52 mm 2 04 in Q 704...

Страница 12: ...56 97 in C 597 mm 23 5 in D 213 mm 8 375 in E 610 mm 24 in F 203 mm 8 in G 391 mm 15 4 in H 60 mm 2 3 in I 938 mm 36 9 in J 368 mm 14 5 in K 1140 mm 44 87 in L 813 mm 32 in M 683 mm 26 875 in N 107 m...

Страница 13: ...ousing IMPORTANT The dryer should have sufficient clear ance around it for needed ventilation and for the ease of installation and servicing For maximum drying per formance we recommend that more clea...

Страница 14: ...299 Central Pay Models The machine is shipped from the factory with the Electronic Con trol Diagnostic Harness Assembly unplugged To avoid unauthor ized manual programming or vending perform the follo...

Страница 15: ...ctures Remove Shipping Materials 1 Remove two screws at bottom of front access panel Rotate bottom of panel out and remove panel FLW2378N_SVG Figure 3 2 Remove two 9 16 inch bolts and washers holding...

Страница 16: ...pliance is to be connected to the water mains using new hose sets and the old hose sets should not be reused Turn on the water supply faucets and flush the lines for approxi mately two minutes to remo...

Страница 17: ...there will be an extended period of non use All Other Models Connecting Hoses 1 Insert rubber washers and filter screens from accessories bag in water fill hose couplings two hoses supplied with wash...

Страница 18: ...tion Owner should turn off water supply whenever there will be an extended period of non use Install Washer Electrical Cord 400 Volt 50 Hertz 9 8 Amp NOTE Refer to 7 14 190 conversion instructions for...

Страница 19: ...outside diame ter drain hose Drain Flow Rate Drain Height Flow Rate liters per minute gal lons per minute 0 9 m 3 ft 27 7 7 3 1 5 m 5 ft 17 8 4 7 1 8 m 6 ft 13 4 3 5 2 1 m 7 ft 4 8 1 3 2 4 m 8 ft 0 0...

Страница 20: ...ocated in the door re cess Use a new flexible stainless steel connector Use pipe joint compound insoluble in L P Lique fied Petroleum Gas or Teflon tape on all pipe threads Purge air and sediment from...

Страница 21: ...Flexible Connector Use design CSA certified connector Use only if allowed by local co des 2 1 8 in NPT Pipe Plug 3 Equipment Shut Off Valve 4 Black Iron Pipe Shorter than 6 1 m 20 ft Use 9 5 mm 3 8 in...

Страница 22: ...econdary lint filters or lint collectors If secon dary systems are mandated frequently clean the system to assure safe operation W749 IMPORTANT Installing in line filters or lint collectors will cause...

Страница 23: ...ty NOTE Venting materials are not supplied with the dry er obtain locally IMPORTANT DO NOT block the airflow at the bottom of the dryer s front panel with laundry rugs etc Block age will decrease airf...

Страница 24: ...er Installation Exhaust Requirements A direct individual outside venting is recommended When that is not possible a collector duct as shown below may be used SWD998N_SVG 4 3 2 1 1 58786 Backdraft Damp...

Страница 25: ...reen or Cap 5 610 mm 24 in Minimum Clearance to Roof Ground 6 Exhaust Outlet 7 Air Flow 8 30 9 Clean Out Cover Inspect Monthly Figure 17 Duct Station Minimum Diameter of Collector Duct A 102 mm 4 inch...

Страница 26: ...al exhaust system Position and Level the Unit WARNING Units elevated above floor level must be anchored to that elevated surface base or platform The material used to elevate the unit should also be a...

Страница 27: ...block 6 Loosen 7 8 in locknut and adjust legs by screwing into or out of unit base until the unit is level from side to side and front to back using a level Unit should not rock NOTE Leveling legs ca...

Страница 28: ...oad circuits DO NOT use an extension cord DO NOT use an adapter DO NOT operate both a washer and a gas dryer on the same circuit Machine Must Be Hard Wired SWD1034N_SVG NOTE Electrical disconnect must...

Страница 29: ...ions MUST abide with local electrical codes It is the customer s responsibility to have the wiring and fuses checked by a qualified electrician to make sure the laundry room has adequate electrical po...

Страница 30: ...ng legs Check Heat Source Electric Dryers 1 Close the loading door and start the dryer in a heat setting re fer to the operation instructions 2 After the dryer has operated for three minutes the exhau...

Страница 31: ...warm DRY212N_SVG 6 5 4 3 2 1 1 Closed Position 2 Shut Off Valve Handle 3 Air Shutter Lockscrew 4 Air Shutter 5 3 1 mm 1 8 in Pipe Plug For checking manifold pres sure 6 Open Position Figure 24 Instal...

Страница 32: ...hing bulky items such as blankets and comforters use the DELICATES BULKY cycle The cycle includes agi tation and final spin speeds that maintain the load s balance and minimize wear to the articles NO...

Страница 33: ...W84R_SVG 40 NORMAL 40 Table continues FLW85R_SVG 60 PERM PRESS 60 FLW86R_SVG 30 DELICATES 30 FLW87R_SVG DELICATES COLD temperature of water from tap NOTE Changes can be made to Fabric Selector setting...

Страница 34: ...d inside of washer control cabi net and check for broken loose or incorrect wiring NOTE Once a cycle has started the door can only be opened by first unplugging the power cord and waiting one minute W...

Страница 35: ...oor 1 Close loading door 2 Dryer will not operate with the door open SWD1032N_SVG Figure 33 Determine Proper Controls The direction of the arrow indicates which control is for which unit SWD960N_SVG F...

Страница 36: ...two minutes every hour without heat up to 18 hours or until door is opened Remove Laundry Remove laundry immediately after dryer stops D719I_SVG Figure 37 WARNING To prevent the risk of fire remove la...

Страница 37: ...rder to assure that the door properly seals against water leaks the following surfaces should be wiped off periodically The outside perimeter of the door glass where the seal con tacts the glass The f...

Страница 38: ...assembly requiring the use of tools must be performed by a suitably qualified service person W299 The exhaust duct should be inspected after one year of use and cleaned if necessary by a qualified ser...

Страница 39: ...set itself Dryer can be restarted by pressing the START pad If overload protector cycles again remove the dryer from use and call the service person to correct the problem For Energy Conservation Make...

Страница 40: ...Make sure door latch is properly adjusted relative to door lock Won t Spin Tumble Make sure power cord is plugged all the way into the electrical outlet Check the laundry room fuse or circuit breaker...

Страница 41: ...e sure washer is level Uneven leveling can cause vibration Make sure washer is installed on a solid sturdy and level floor The washer should not be installed on carpeting soft tile a platform or other...

Страница 42: ...ng Check weather hood to make sure flapper moves freely has not been pushed in or has not been blocked Dryer doesn t dry clothes satisfactorily Check exhaust duct to outside to see if it is kinked blo...

Страница 43: ...erly and may cause wrinkling Clothes have odor Check room for odors before drying clothes Any odor fried foods paint varnish cleaners burning wood etc will trans fer to clothing as the dryer draws air...

Страница 44: ...En suring this product is disposed of correctly will help prevent po tential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling...

Страница 45: ..._______ Model Number ______________________________ Serial Number _______________________________ Please include a copy of your bill of sale and any service receipts you have WARNING To reduce the ris...

Страница 46: ......

Страница 47: ......

Страница 48: ...ums SWD1030N_SVG CHECK CHECK 4 Install Washer Electrical Cord SWD1022N_SVG1 10 Connect Unit to Elec trical Power SWD1034N_SVG CHECK CHECK 5 Connect Drain Hose to Drain Receptacle or Drain Outlet to Dr...