![grandimpianti 805898ENR1 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/grandimpianti/805898enr1/805898enr1_installation-and-operation-manual_2255210020.webp)
Gravity Drain Models - Connect Drain
Outlet to Drain System
1.
Remove drain fitting (102 mm [4 inches] long) and hose
clamp from accessories bag. Insert drain fitting into drain out-
let hose. Clamp hose and fitting.
2.
Connect the drain fitting to a vented drain system using a
flexible connection (obtain locally). Inside diameter of fitting
is 39 mm [1.53 in.] and outside diameter is 42 mm [1.66 in.].
3.
The drain system must be vented to prevent an air lock or si-
phoning.
IMPORTANT: Increasing the drain hose length, in-
stalling elbows, or causing bends will decrease
drain flow rates and increase drain times, impairing
machine performance.
SWD1002N_SVG
2
1
1.
Drain Trough
2.
Drain Outlet Hose
Figure 13
Gas Dryers - Connect Gas Supply Pipe
(5.9 kW)
Gas Rate = 0.55 m
3
/hr.
NOTE: This appliance must be installed in accordance
with regulations in force.
NOTE: This machine is supplied from the factory for
operation on Natural Gas (2nd Family, Group H[E]) at
nominal inlet pressure of 20 mbar for use in the coun-
tries of GB/IE/PT/ES/IT/BE. For installation in other EU
Countries, and/or for conversion to L.P. (Liquefied Pe-
troleum) gas, consult the distributor
WARNING
To reduce the risk of gas leaks, fire or explosion:
• The dryer must be connected to the type of gas
as shown on nameplate located in the door re-
cess.
• Use a new flexible stainless steel connector.
• Use pipe joint compound insoluble in L.P. (Lique-
fied Petroleum) Gas, or Teflon tape, on all pipe
threads.
• Purge air and sediment from gas supply line be-
fore connecting it to the dryer. Before tightening
the connection, purge remaining air from gas line
to dryer until odor of gas is detected. This step is
required to prevent gas valve contamination.
• Do not use an open flame to check for gas leaks.
Use a non-corrosive leak detection fluid.
• Any disassembly requiring the use of tools must
be performed by a suitably qualified service per-
son.
W316
These instructions are only valid if the following country code is
on the appliance - GB/IE/PT/ES/IT/BE. If this code is not present
on the appliance, it is necessary to refer to the technical instruc-
tions which will provide the necessary information concerning
the modification of the appliance to the condition of use for the
country.
Before installation, check that the local distribution conditions,
nature of gas and pressure, and the adjustment of the appliance
are compatible.
1.
Make certain your dryer is equipped for use with the type of
gas in your laundry room. Dryer is equipped at the factory for
Natural Gas with a 3/8 inch NPT gas connection.
NOTE: The gas service to a gas dryer must conform
with the local codes and ordinances.
Installation
©
Published by permission of the copyright owner -
DO NOT COPY or TRANSMIT
20
Part No. 805898ENR1