GRAINPRO
®
CARBON DIOXIDE ANALYZER
INSTRUCTION MANUAL
MA4068RAD0718-1
Страница 1: ...GRAINPRO CARBON DIOXIDE ANALYZER INSTRUCTION MANUAL MA4068RAD0718 1...
Страница 2: ...CEDURES 8 5 1 Power On 8 5 2 Initialization 8 5 3 Setting Mode 9 5 4 Sampling Mode 9 5 5 Download Reset Mode 11 5 6 Monitoring Battery Charge 20 5 7 Calibration Mode 20 6 USING CARBON DIOXIDE ANALYZER...
Страница 3: ...ack It is powered by a 7 4V Li ion rechargeable battery 1 1 FEATURES 1 1 1 Portable 1 1 2 More than 5 years sensor expected life span 1 1 3 Backlit 20 x 4 Alphanumeric OLED display 1 1 4 Microprocesso...
Страница 4: ...MAGE 2 1 CO2 Analyzer 2 1 1 CO2 Analyzer 0 80 range IR sensor with Rechargeable Battery 7 4 V 1500 mAH Li ion 2 2 Battery Charger 2 2 1 Battery Charger 110V 250VAC with 4 different types of interchang...
Страница 5: ...CO2 Analyzer to a computer 2 6 USB Flash Drive 2 6 1 USB Flash drive includes a Software b CO2 Analyzer Instruction Manual c Instruction Video d GP Audio Visual Presentation e Flyer All GP Products 2...
Страница 6: ...Dioxide Analyzer Instruction Manual MA4068RAD0718 1 2 9 Instruction Manual 2 9 1 Instruction manual for CO2 Analyzer 3 COMPONENTS COMPONENTS DESCRIPTION FUNCTION Figure 1 Carbon Dioxide Analyzer Batte...
Страница 7: ...s placed d Settings Mode Key is where setting and Turn off are located In Setting this Key is used to increase the value of the digit on which the cursor is placed e Download Reset Mode In this mode y...
Страница 8: ...8 Display It is a 20 x 4 alphanumeric OLED display which indicates a Various prompts during initialization process immediately after turning ON the CO2 Analyzer b CO2 concentration Date and Time in t...
Страница 9: ...ll Scale range but also depends on the accuracy of the calibrating gas method Battery 7 4 V 1500 mAH Li ion Rechargeable Battery Charger Input 100 240V 50 60Hz 0 6A Max Output 8 4V 10A Operating Tempe...
Страница 10: ...charger before using the device NOTE Charge until the Red LED on the charger turns Green See section 5 6 3 5 1 2 After fully charge press and hold the Set Key for 3 4 seconds 5 1 3 Green LED marked PO...
Страница 11: ...DN Key for Calibration c SET Key for Settings d ENT Key for Download Reset 5 3 Setting Mode 5 3 1 Accessing parameter setting mode a From the Main Menu press the SET Key to enter into the setting page...
Страница 12: ...for increasing the value 0 to 9 and Down Key to shift the cursor Then press ENT Key to confirm d To change Date and Time use Up Key for increasing the value 0 to 9 and Down Key to shift the cursor Th...
Страница 13: ...s from the surrounding environment 5 4 5 If the Sampling mode is selected a CO2 analyzer will display prompt to verify if the tubes were already removed b Press Enter Key to start Zero Check about 7 s...
Страница 14: ...ift 8 5 5 5 Download Reset Mode 5 5 1 INSTALLATION AND DOWNLOADING FOR WINDOWS 5 5 1 1 Software Installation for Windows a Install Uniphos Terminal Software from USB Flash drive provided along with th...
Страница 15: ...Driver go back to the USB Flash drive files and open the MY_TERMINAL_V_1 1 folder i Open the Volume folder and Install the application 5 5 1 2 Download Data for Windows a After the installation short...
Страница 16: ...com port number search for Device Manager Go to Ports COM LPT click on the drop down list and get the com port number e Go back to the Uniphos Terminal Window and select the com port number NOTE Gener...
Страница 17: ...summary or range of reading on your computer press Up Key i While downloading number of readings will also appear on the screen j Summary of data will be displayed on the Uniphos Terminal on your comp...
Страница 18: ...1 5 5 2 1 Software Installation for Linux a Install gtkterm from Ubuntu Software on your computer b Open Ubuntu Software c On the search bar type gtkterm d Click on the Serial Port Terminal gtktern an...
Страница 19: ...al and check USB Serial port connection b While the CO2 Analyzer is not connected type the command dmesg grep tty on the terminal c No USB connection shall appear d Connect the CO2 Analyzer with your...
Страница 20: ...connection of your CO2 Analyzer Baud Rate 9600 Parity none Bits 8 Stopbits 1 other parameters as default Click OK after h Next click on Log from the menu and choose to file i Window for saving files w...
Страница 21: ...nloading of the data to the terminal software is done go back to Control Signals and click Close Port n Check on the Log file data You can open either with Text Editor or any spreadsheet app on Linux...
Страница 22: ...NSTALLATION AND DOWNLOADING FOR MAC 5 5 3 1 Software Installation for MAC a Open MAC Folder from USB Flash Drive provided along with the CO2 Analyzer b Open FTDI USB DRIVER folder c Choose driver matc...
Страница 23: ...3 25 GrainPro Carbon Dioxide Analyzer Instruction Manual MA4068RAD0718 1 e Installation window will appear after Just click on continue and install f Go Back to MAC folder and choose TERMINAL SOFTWARE...
Страница 24: ...pen dmg file h Window from dmg file will appear Click on CoolTerm after i CoolTerm software will appear 5 5 3 2 Download Data for MAC a Open MAC s Terminal to check USB Serial port connection b While...
Страница 25: ...r via USB Cable provided e In the terminal type again the command ls dev tty USB connection shall appear on the terminal f Open CoolTerm software again g From the menu click Options h From the Serial...
Страница 26: ...om the Main Menu j Choose Capture to Textfile from the drop down list and click Start k Window Select a filename and destination for the capture data will appear Create a file and Save l After setting...
Страница 27: ...close CoolTerm p Check on the saved capture data You can open either with TextEdit or MAC iWork s Numbers or other file viewing app 5 5 4 Erase Data on CO2 Analyzer a Press the Down Key to erase all t...
Страница 28: ...to main Menu 5 6 Monitoring Battery Charge 5 6 1 Battery Status Battery status can only be monitored when the CO2 Analyzer is in the Data downloading page 5 6 2 Battery Low When the battery capacity g...
Страница 29: ...ion mode b Enter the Password 321 and expose to ambient air or connect to pure nitrogen c Press Enter Key to confirm then the CO2 Analyzer is ready for Zero calibration d The Apply Zero Gas prompt wil...
Страница 30: ...ompt will appear on screen and will ask for Span Gas Value j CO2 Analyzer will be calibrated only if counts value for applied span gas is within valid range i e from 1000 to 4030 display counts ideall...
Страница 31: ...or damages CO2 level of ambient air is 0 03 to 0 04 7 MAINTENANCE AND CARE 7 1 Do a regular monthly battery checkup and recharge it fully before use Charge the instrument until Red LED on charger turn...
Страница 32: ...bnormal noise There may be a blockage in the gas sampling tube or in the nozzles Clear blockage 8 4 The instrument does not turn On Low battery Recharge Battery 8 5 Sensor Drift Count value is lower t...
Страница 33: ...ked just input continuously and press enter again 4 To add dialout type in the command sudo usermod a G dialout USERNAME and press enter 5 Type in the command group again Notice if tty and dialout is...
Страница 34: ...red light dispersed according to its wavelength sensor often used as a gas detector It is nondispersive in the sense of optical dispersion since the infrared energy is allowed to pass through the atmo...
Страница 35: ...parts thereof if the defect is a result of any of the following normal wear and tear damages occurring after delivery accidents acts of God or catastrophes fault or negligence or improper storage ins...