GM · CONVERTING UNIT
13
CAUTION:
Never use flammable solvents near the UV dryer when the lamps are in
operation. If a fire should break out, only use fire extinguishers of the dry powder
type.
e.
High voltages
UV lamps operate at high voltages (450V - 1400V) depending on the lamp type; additionaly when
striking the lamps, ignitor circuitry will generate pulses in excess of 2kV. These high voltages present a
danger of electric shock or fire.
Other equipment mounted in the vicinity of the UV dryer should not interfere with the safe operation of
the system.
NOTE:
When testing/troubleshooting the system, make sure that all cables are
intact and all safety interlocks in place.
5.7.
The die-cutting station
This converting unit is equipped with a die-cutting station, which can run in several modes. Correct setup
is crucial to the operation of the die-cutting station. To enter the die-cut setup menu, press the button 'Die-
cut parameters'.
To raise and lower the die-cut cylinder, press the cylinder symbol. When the cylinder is up, the symbol is
green. When the cylinder is down (engaged), the symbol is yellow.
When the cylinder is activated in the touch panel, it will not be physically engaged if the die-cut station is
initializing, or if the die-cut feature has been turned off in the die-cut parameters menu.