www.graf.info
19 / 39
7.
Assembly of the adapter
7.1
Assembling the adapter
For lager coverage heights a adapter is needed. To insert the adapter into the tank dome, soft soap is
needed. Into the highest groove of the adapter the profile seal is inserted an greased generously.
Afterwards push the telescopic dome shaft into the adapter and adapt it to the planned area surface.
1 Adapter = max. earth-cover 955 mm respectively 1055 mm
(in connection with Mini respectively Maxi telescopic dome shaft)
8.
Inspection and servicing
The entire system must be checked for leaks, cleanliness and stability at least every three months.
The entire system should be serviced at intervals of approx. 5 years. In this case, all parts of the system
must be cleaned and their function checked. Servicing should be carried out as follows:
Drain the tank completely
Clean surfaces and internal parts with water
Remove all dirt from the tank
Check that all internal parts are firmly seated.
Telescopic dome shaft (can be inclined by 5°)
Adapter
Profile seal
Tank dome Platin
Otto Graf GmbH
– Carl-Zeiss-Str. 2-6 – D-79331 Teningen – Tel.: 0049/(0)7641/589-0 – Fax: 0049/(0)7641/589-50
GRAF SARL
– 45, Route d´Ernolsheim – F-67120 Dachstein Gare – Tel.: 0033/388497310 – Fax: 0033/388493280
GRAF Iberica
– C/Marquès Caldes de Montbui, 114 baixos – ES-17003 Girona – Tel.: +34/972 913 767 – Fax: +34/972 913 766
GRAF Ltd
– Maidstone, Kent – UK-ME16 8Ry – Phone: +44 (0) 16 22 68 65 50
10-2011