Troubleshooting
313875J
51
Troubleshooting
For information about ADM error and event codes see
Appendix D - ADM Event and Error Codes Overview
page 69.
Before performing any troubleshooting procedure:
1.
Perform
on page 46.
2.
Turn Main Power Switch to the OFF position.
3.
Allow equipment to cool.
Try the recommended solutions in the order given for
each problem to avoid unnecessary repairs. Also, deter-
mine that all circuit breakers, switches, and controls are
properly set and wiring is correct before assuming there
is a problem.
Light Tower (Optional)
Errors include advisories, deviations, or alarms, so
green will only be on when none of these occur. A yellow
light can be on at the same time as red (flashing or solid
on) when an advisory exists at the same time as a devi-
ation or alarm.
Common Problems
Signal
Description
Green on only
System is powered up and there are
no error conditions present
Yellow on
An advisory exists
Red flashing
A deviation exists
Red on
The system is shut down due to an
alarm occurring.
Problem
Cause
Solution
General
Display Module completely
dark
No power
Verify main power switch is ON
Thrown circuit breaker
Check machine breakers and reset
Loose connection
Tighten 5-pin cable on Advanced Display Module
Bad display module
Replace Advanced Display Module
No or incorrect amount of
material dispensed from
either side
Tank empty
Install new drum of fluid
Air in material
Prime the machine
Significant material leaking
from pump seal
Pump shaft worn and/or shaft seal
worn
Remove pump shaft assembly and reinstall, see
pump manual for instructions and rebuild kit
Material dispensed not cor-
rect weight
Specific gravity of one or more of the
two materials has changed since cali-
bration
Perform calibration procedure
Check valve malfunction
Remove check valve; clean or replace as necessary
Piston worn or broken
Replace piston
Proportioning System
Proportioning pump does not
hold pressure when stalled
Pump piston or intake valve leaking
1.
Observe gauges to determine which pump is los-
ing pressure.
2.
Determine in which direction the pump has
stalled by observing which directional valve indi-
cator light is on.
3.
Repair the valve.
Содержание VPM 12
Страница 9: ...A Red and B Blue Components 313875J 9...
Страница 11: ...Component Identification 313875J 11 FIG 2 Component Identification ti17702a AJ AF AL AD AC VPM 25 shown...
Страница 12: ...Component Identification 12 313875J VPM 12 FIG 3 ti17703a AL AA AK AH AE AB AD AF AJ AL AD AC AC...
Страница 50: ...Maintenance 50 313875J...
Страница 86: ...Appendix E USB Operation 86 313875J...