Clean-Up for ThermoLazer ProMelt
3A1319K
35
Clean-Up for ThermoLazer ProMelt
1. Secure unit by chocking all three wheels.
NOTE:
Flow can be increased by propping up the
left rear wheel and securing unit by chocking the
other two wheels.
2. Fully engage and lock brake.
3. Rotate agitator handle to 9 o’clock and hold at this
position by using the cover latch.
4. Turn kettle burners ON to melt material.
5. Open material gate and pour out remaining material
in a heat-resistant container.
6. Turn kettle burners OFF.
7. Use long-handled scraper tool (VV) to remove
material from inside of kettle. Start by scraping from
the top of the kettle sides and work your way down
so that as soon as the material collecting at the bot-
tom begins to cool and harden you can scoop it out
of the kettle. Collect material in a heat-resistant pan.
NOTE:
If material becomes too hard to scrape or
remove, reheat the kettle until the material becomes
soft again.
8. Repeat step 7.
9. Rotate agitator handle to 3 o’clock and hold at this
position by using the cover latch.
10. Use small scraper to clean out trough, screed box,
and agitators.
Transporting
Remove LP-Gas supply cylinder from the unit before
transporting. Secure in an approved location and
method as authorized by local, state, federal, national,
and international agencies.
Always use the designated mounted lifting rings when
lifting the unit. When lifting the unit, only use ANSI
approved slings and equipment rated for a minimum of
2000 lb. Always use ANSI approved equipment for
securing the unit to transporting equipment.
BURN HAZARD
Never scoop out remaining melted thermoplastic from
kettle without proper Personal Protective Equipment.
ti14603a
ti15950a
NOTICE
Be sure to thoroughly clean all material out of screed
box and any open areas to prevent material from freez-
ing moving parts of screed box. Always run all material
out of each screed box before removing. Scrape out all
remaining material before it sets within the screed box.
NOTICE
To prevent material from hardening and blocking flow,
scrape all excess material off of external surfaces after
each use.
NOTICE
Remove any remaining beads in the bead hopper and
bead dispenser to prevent beads from clogging hopper
and dispenser.
ti14529a