Repair
30
3A7939A
Reconnect the Pump
See the
section starting on page 32 for all part
identification references in the steps below.
WLD
WLD
9
8
1. Screw the connecting rod adapter (11) to the motor
shaft.
2. Screw the tie rods (8) into the motor (4). Using a
wrench on the tie rod flats, torque to 50-60 ft-lb
(68-81 N•m).
3. Make sure the coupling nut (13) and coupling collars
(12) are in place on the rod.
4. Use at least two people to hold the pump while
another person reconnects it to the motor. Position
the pump as shown below. Place the pump (9) on
the tie rods (8).
NOTE:
When reconnecting the pump (9) to the
motor (4), be sure to match the relative position of
the pump’s disinfectant outlet to the motor.
WLD
TSL
D
5. Screw the nuts (10) onto the tie rods (8) and torque
to 50-60 ft-lb (68-81 N•m).
6. Screw the coupling nut (13) onto the connecting rod
adapter (11) loosely. Hold the connecting rod
adapter flats with a wrench to keep from turning.
7. Use an adjustable wrench to tighten the coupling
nut (13). Torque to 90-100 ft-lb (121-135 N•m).
8. Reconnect all hoses. Fill the packing nut (D) 1/3 full
of Graco Throat Seal Liquid.
9. Turn on the electric motor. Run the pump slowly to
ensure that it operates properly.
Use at least two people when lifting, moving, or
connecting the pump. When connecting the pump, be
sure to securely brace the pump, or have two people
hold it while another person connects it.