![Graco SaniSpray HP 750 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/graco/sanispray-hp-750/sanispray-hp-750_instructions-manual_2251760021.webp)
WLD
Spray
3A7939A
21
c. Trigger each gun into a grounded metal pail.
d. Pull out the pressure adjustment knob (H) and
turn it clockwise slowly to increase pressure
until a steady stream flows from the gun. Push
the knob in to lock.
e. Trigger each gun for at least one minute, then
release the trigger.
f.
Close the ball valve for the gun you have just
flushed, then trigger the gun again to relieve
pressure.
g. Engage trigger lock.
NOTE:
If flushing one gun at a time, proceed to
the next gun in the line (described in the note
below step 7a). Repeat steps 7b - 7e for each
gun.
WLD
inner
outer
position
4
position
3
position
2
position
1
h. To make sure the entire 4-gun manifold is
completely flushed, trigger the gun at the
outer-most ball valve furthest from sprayer
(position 1) for an additional 30 seconds after
flushing the other hoses. This will ensure there
is no disinfectant left in the manifold.
NOTE:
Flush all hoses and guns used at any
point during spraying (even if you only opened
the ball valve but did not spray the gun).
i.
Engage all trigger locks.
NOTE:
If using an 8-gun setup, be sure to
repeat steps to flush the hoses and guns for
both 4-gun manifolds.
8. Wipe the sprayer and all hoses with a soft cloth
moistened with warm soapy water.
9. Dispose of unused disinfectant in the waste pail
according to instructions on the disinfectant
container label and follow all applicable regulations.
Clean the Guns
1. Follow the
2. Remove the spray tips, tip guard assemblies, and
gun extensions (if installed), then clean with warm
soapy water and a brush.
3. Wipe the spray guns with a soft cloth moistened
with warm soapy water.
Содержание SaniSpray HP 750
Страница 13: ...Setup 3A7939A 13 4 Gun Setup WL D ...
Страница 14: ...Setup 14 3A7939A 8 Gun Setup WL D ...
Страница 34: ...Parts 34 3A7939A 4 Gun Manifold 273226 Parts WL D ...