Setup
Setup
Setup
To avoid contaminating the fluid, pipe the exhaust
air to vent outside of the fluid product area, away
from people, animals, or food handling areas.
Note
Reference numbers and letters in
parentheses in the text refer to the callouts in
the figures and the parts drawings.
Accessories are available from Graco. Make certain
all accessories are sized and pressure rated to meet
your system requirements.
Figure 6 is only a guide for selecting and installing
system components and accessories. Contact your
Graco distributor for assistance in designing a system
to suit your particular needs.
1.
Connect the master air supply to the 1/2 npt(f)
main air inlet valve (B). The incoming air pressure
maximum is 100 psi (0.7 MPa, 7 bar).
2.
Verify that the elevator air supply connections (Y)
did not loosen during shipping.
3.
Connect air tubing from the 1/2 npt(f)
push-to-connect fitting (X) to the pump air inlet
(D).
Air
Air
Air Controls
Controls
Controls
Figure 5
Key
Key
Key
B
Main air inlet valve
R
Pump air pressure regulator
S
Pump air pressure gauge
T
Pump air switch, 2 position
U
Elevator air pressure regulator
V
Elevator air pressure gauge
W
Elevator director switch, 3 position
X
Air outlet to pump
Y
Air outlet to elevator
NOTE:
NOTE:
NOTE: If using an electric progressive cavity pump,
set pump air pressure regulator on the elevator
control panel to zero air pressure. These controls are
not needed for pump operation.
12
333406D
Содержание SaniForce 24V311
Страница 21: ...Notes Notes Notes Notes 333406D 21 ...
Страница 22: ...Parts Parts Parts Parts Parts Parts Parts 22 333406D ...
Страница 24: ...Parts Sanitary Sanitary Sanitary Elevator Elevator Elevator Kit Kit Kit 24V299 24V299 24V299 24 333406D ...
Страница 26: ...Parts Air Air Air Controls Controls Controls Kit Kit Kit 24V172 24V172 24V172 26 333406D ...
Страница 33: ...Dimensions Dimensions Dimensions Dimensions 333406D 33 ...