Repair
313540L
31
Circuit Breaker Module
1. Turn main power OFF
. Disconnect power
supply. Turn circuit breakers on to test.
2. Relieve pressure, page 28.
3. Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and to T
connect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
Table 3: Circuit Breakers, see F
Ref. Size
Component
809
50A
Hose/Transformer
Secondary Side
811
40A
Transformer
Primary
812A
50A
Heater A
812B
50A
Heater B
813
20A
Motor/Pumps
F
IG
. 5. Circuit Breaker Module
ti9884a
812A
813
809
811
NOTE:
To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on page 65.
812B