Home Screen
Screen
Screen
Use the Home screen to control the Reactor
system operation functions.
Temperature
Temperature
Temperature Control
Control
Control Panel
Panel
Panel
The Temperature Control panel contains
controls for Hose heat and A and B-side Primary
heaters.
Icon
Icon
Icon
Name
Name
Name
Description
Description
Description
Primary
Heater A
On/Off
Tap to toggle the A primary heater
state.
Primary
Heater B
On/Off
Tap to toggle the B primary heater
state.
Hose Heat
On/Off
Tap to toggle the hose heat state.
A (ISO)
Tempera-
ture Set-
point
Tap +/– to adjust the setpoint by
one degree. Press and hold +/- to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly.
B (RES)
Tempera-
ture Set-
point
Tap +/– to adjust the setpoint by
one degree. Press and hold +/- to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly
Hose
Current
Setpoint
Tap +/– to adjust the setpoint by
one amp. Press and hold +/– to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly.
NOTE:
NOTE:
NOTE: The Hose Current Setpoint
button is only displayed if the Hose
Control Mode is set to Manual in
the
settings.
Reset Auto
Pressure
Balance
Tempera-
ture Offsets
Tap to reset the Auto Pressure
Balance temperature offset values
(to the left and right of this button).
A
A
A and
and
and B
B
B side
side
side Supply
Supply
Supply Control
Control
Control Panels
Panels
Panels
The A and B Supply Control panels display the
remaining material supply for A and B side
materials, and contains controls for electric
transfer pumps (if applicable).
Icon
Icon
Icon
Name
Name
Name
Description
Description
Description
Electric
Transfer
Pump A
On/Off
Press to toggle the A electric
transfer pump state.
NOTE:
NOTE:
NOTE: This button is only
displayed if an electric transfer
pump is installed and the
proportioner pump state is off.
The electric transfer pumps are
automatically turned on any
time the proportioner pump is
turned on.
Electric
Transfer
Pump B
On/Off
Press to toggle the B electric
transfer pump state.
NOTE:
NOTE:
NOTE: This button is only
displayed if an electric transfer
pump is installed and the
proportioner pump state is off.
The electric transfer pumps are
automatically turned on any
time the proportioner pump is
turned on.
A (ISO)
Transfer
Pump Jog
Level
Tap +/– or the displayed jog
level number (i.e. J10) to set
the A-side transfer pump jog
level.
NOTE:
NOTE:
NOTE: Jog levels are between 1
and 20.
.
B (RES)
Transfer
Pump Jog
Level
Tap +/– or the displayed jog
level number (i.e. J10) to set
the B-side transfer pump jog
level.
NOTE:
NOTE:
NOTE: Jog levels are between 1
and 20.
.