Setup
Setup
Setup Screens
Screens
Screens
Use the Setup screens screens to edit settings
for the Reactor system.
Pressure/Flow
Pressure/Flow
Pressure/Flow
Use the Pressure/Flow screen to set pressure
monitoring settings for the Reactor system.
Setting
Setting
Setting
Description
Description
Description
Enable Auto
Pressure Balance
This feature monitors the pressure
imbalance while material is flowing
and adds temperature offsets to the
setpoints to minimize the pressure
imbalance.
Tap the checkbox to enable/disable
Auto Pressure Balance. Tap
the number value to adjust the
temperature offset limit allowed
using Auto Pressure Balance.
NOTE:
NOTE:
NOTE: This feature is only enabled
on Pro and Elite models.
Enable Pressure
Imbalance Alarms
Tap the checkbox to enable/disable
Pressure Imbalance Alarms. Tap the
number value to adjust the alarm
threshold.
NOTE:
NOTE:
NOTE: Pressure imbalance alarms are
automatically enables if flow meters
are enabled.
Enable Pressure
Imbalance
Deviations
Tap the checkbox to enable/disable
Pressure Imbalance Deviations. Tap
the number value to adjust the
deviation threshold.
Enable Reactor
Smart Control
Tap the checkbox to enable/disable
Reactor Smart Control. This feature
does the following:
• Slows down the proportioner pump
if inlet pressure is low. This is
done to allow the transfer pumps
to keep up and avoid off-ratio
conditions.
• Controls the output pressure to the
average of the A and B pressure
sensors (instead of the max).
Enable Flow
Meters
Tap the checkbox to enable/disable
flow meters.
Enable Flow Meter
Alarms
Tap the checkbox to enable/disable
flow meter alarms. Tap the number
value to adjust the alarm threshold.
NOTE:
NOTE:
NOTE: Flow meter alarms are only
available when flow meters are
installed.
Flow Meter A
K-Factor
Tap the number value to enter the
K-Factor for the A side flow meter.
NOTE:
NOTE:
NOTE: The K-Factor is noted on the
meter label.
Flow Meter B
K-Factor
Tap the number value to enter the
K-Factor for the B side flow meter.
NOTE:
NOTE:
NOTE: The K-Factor is noted on the
meter label.
Enable Maximum
Pressure Setpoint
Tap the checkbox to enable/disable
a user defined maximum pressure
setpoint. Tap the number to adjust
the maximum pressure setpoint that
can be entered on the home screen.
Enable Minimum
Pressure Setpoint
Tap the checkbox to enable/disable
a user defined minimum pressure
setpoint. Tap the number to adjust
the minimum pressure setpoint that
can be entered on the home screen.
Enable Jog Limit
Tap the checkbox to enable/disable
the jog limit feature. Tap the number
to adjust the jog cycle limit. When
enabled and in jog mode, the Reactor
pump will automatically shutoff
when the specified number of cycles
are completed.
NOTE: This feature can be enabled
directly on the home screen.
48
3A8500B