background image

Repair

Replace

Replace

Replace HCM

HCM

HCM

1.

Follow

Before Beginning Repair, page 51

.

2.

Open the electrical enclosure and disconnect all
cables from the HCM (603).

3.

Remove the nuts (610) and HCM (603).

4.

Set rotary switch.

Figure 13 Replace HCM

HCM

HCM

HCM Rotary

Rotary

Rotary Switch

Switch

Switch Positions

Positions

Positions

0 = Reactor 2, H-30

1 = Reactor 2, H-40

2 = Reactor 2, H-50

3 = Reactor 2, H-XP2

4 = Reactor 2, H-XP3

Replace

Replace

Replace ADM

ADM

ADM

1.

Loosen four screws (70) on inside of electrical
enclosure door (61). Lift up and pull out to
remove ADM (88).

2.

Disconnect CAN cable (475).

3.

Inspect ADM (88) for damage. Replace if
necessary.

Figure 14

66

334946C

Содержание Reactor 2

Страница 1: ...polyurea coatings coatings coatings Not Not Not for for for outdoor outdoor outdoor use use use For For For professional professional professional use use use only only only Not Not Not approved appr...

Страница 2: ...ertemperature Switch 58 Replace RTD 59 Repair Heated Hose 60 Repair Fluid Temperature Sensor FTS 62 Repair Circuit Breaker Module 63 Transformer Primary Check 64 Transformer Secondary Check 64 Replace...

Страница 3: ...th if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS for handling instructions and to know the specific hazards of the fluids you are using including the effects of lo...

Страница 4: ...N EXPLOSION HAZARD HAZARD HAZARD Flammable fumes such as solvent and paint fumes in work work work area area area can ignite or explode Paint or solvent flowing through the equipment can cause static...

Страница 5: ...on and equipment rupture Failure to follow this warning can result in death serious injury or property damage Do not use 1 1 1 trichloroethane methylene chloride other halogenated hydrocarbon solvents...

Страница 6: ...eplacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environmen...

Страница 7: ...inhalation of isocyanate mists vapors and atomized particulates everyone in the work area must wear appropriate respiratory protection Always wear a properly fitting respirator which may include a sup...

Страница 8: ...e Moisture Moisture Moisture Sensitivity Sensitivity Sensitivity of of of Isocyanates Isocyanates Isocyanates Exposure to moisture such as humidity will cause ISO to partially cure forming small hard...

Страница 9: ...Instructions Parts 332735 Air Manifold Kit Instructions Parts 3A3010 Caster Kit Instructions Parts 333276 Graco InSite Kit Instructions Parts 3A3084 Elite Kit Instructions Part Accessories Accessories...

Страница 10: ...246102 AHH031 246102 APH032 246102 AHH032 246102 APH131 246102 AHH131 246102 APH132 246102 AHH132 246102 Fusion Fusion Fusion CS CS CS Package Package Package Gun Part No CSH031 CS02RD CHH031 CS02RD...

Страница 11: ...APH144 246102 AHH144 246102 Fusion Fusion Fusion CS CS CS Package Package Package Gun Part No CSH043 CS02RD CHH043 CS02RD CSH044 CS02RD CHH044 CS02RD CSH143 CS02RD CHH143 CS02RD CSH144 CS02RD CHH144...

Страница 12: ...46102 AHH145 246102 APH146 246102 AHH146 246102 Fusion Fusion Fusion CS CS CS Package Package Package Gun Part No CSH045 CS02RD CHH045 CS02RD CSH046 CS02RD CHH046 CS02RD CSH145 CS02RD CHH145 CS02RD CS...

Страница 13: ...102 AHH156 246102 Fusion Fusion Fusion CS CS CS Package Package Package Gun Part No CSH053 CS02RD CHH053 CS02RD CSH056 CS02RD CHH056 CS02RD CSH153 CS02RD CHH153 CS02RD CSH156 CS02RD CHH156 CS02RD Prob...

Страница 14: ...n Fusion AP AP AP Package Package Package Gun Part No APH062 246101 AHH062 246101 APH162 246101 AHH162 246101 Probler Probler Probler P2 P2 P2 Package Package Package Gun Part No P2H062 GCP2R1 PHH062...

Страница 15: ...APH074 246102 AHH074 246102 APH076 246102 AHH076 246102 APH174 246102 AHH174 246102 APH176 246102 AHH176 246102 Probler Probler Probler P2 P2 P2 Package Package Package Gun Part No P2H074 GCP2R2 PHH0...

Страница 16: ...tions Deviations A parameter critical to the process has reached a level requiring attention but not sufficient enough to stop the system at this time Advisories Advisories Advisories A parameter that...

Страница 17: ...r wiring Check wiring for touching wires A4DB Heater B High Current B Bad Heater Confirm resistance of heater Heater resistance should be 18 21 for each heater element 9 12 combined for 10 kW systems...

Страница 18: ...ion A8DA Heater A No Current A Loose broken connection Check heater wiring for loose wires Tripped circuit breaker Visually check circuit breaker for a tripped condition A8DB Heater B No Current B Loo...

Страница 19: ...H XP2 3 H XP3 4 No 24 VDC supply to module Green light on each module should be lit If green light is not lit check to make sure each CAN cable connection is tight Verify the power supply is outputti...

Страница 20: ...ower supply wiring If wiring is okay replace the power supply CACT TCM TCM Communication Error Loose or broken CAN cable Check the CAN cables running between GCA modules and tighten of needed If the p...

Страница 21: ...le USB download up loads on the Advanced Setup screen before insert ing a USB drive H2MA Heater A Low Frequency A Line frequency is below 45 Hz Ensure line frequency of incoming power is between 45 an...

Страница 22: ...s are not downloaded Insert a USB drive into the ADM and download all logs Pressure difference between A and B material is greater than the defined value Ensure material flow is equally restricted on...

Страница 23: ...e with a pipe plug P0BX HCM Pressure Imbalance B High Feed system defective Check feed pump and hoses for blockage Check that feed pumps have correct air pressure Inlet pressure lower than defined val...

Страница 24: ...DM pressure reading and the analog gauges at the manifold Replace transducer if they do not match P4AX HCM High Pressure A H XP2 or H XP3 system configured as H 30 H 40 or H 50 Alarm level is lower fo...

Страница 25: ...ed and all wires are properly connected P6BX HCM Pressure Sensor Error B Bad sensor Check if the error follows the transducer Disconnect transducer cables from the HCM connectors 6 and 7 Reverse A and...

Страница 26: ...eck if the errors follows If the error follows the sensor replace the inlet sensor Pressure difference between A and B material is greater than the defined value Ensure material flow is equally restri...

Страница 27: ...SSURE RELIEF SPRAY valve are plugged Clear Replace rupture disk Do not replace with a pipe plug P7BX HCM Pressure Imbalance B High Feed system defective Check feed pump and hoses for blockage Check th...

Страница 28: ...for loose heater element wires Flow is too high at current setpoint Use a smaller mix chamber that is rated for the unit in use If recirculating decrease flow or decrease temperature setpoint T2DH Ho...

Страница 29: ...ose FTS is in a colder environment than the rest of the hose Expose FTS to the same environment as the rest of the hose High ambient temperature Ensure ambient temperature is below 120 F 48 C before u...

Страница 30: ...TCM fan for debris and clear with forced air if necessary Bad RTD or bad RTD placement against heater Swap A and B heater output cables and RTD cables and see if issue follows If so replace RTD T4DA H...

Страница 31: ...Hose Cold ambient temperature is causing hose to heat Cold ambient temperature is chilling the FTS and causing hose heat to stay on longer than needed Insulate the FTS area of the hose so that it hea...

Страница 32: ...red when the heater temperature falls below 190 F 87 C Disconnected or loose overtemperature switch cable connection If heater is not actually over temperature check all wiring and connections between...

Страница 33: ...ure hose RTD cable and FTS continuity See Repair Heated Hose page 60 Order RTD Test kit 24N365 for measure ment Disconnect hose RTD and use manual hose mode to finish job until repair can be completed...

Страница 34: ...output cables and RTD cables and see if issue follows If so replace RTD Bad heater element Confirm resistance of heater Heater resistance should be 9 12 for 10 kW systems 6 8 for 15 kW systems 4 6 for...

Страница 35: ...V2MB TCM Low Voltage B Low incoming line voltage Measure voltage at circuit breaker and ensure voltage is greater than 195 VAC Loose connection or tripped circuit breaker Check wiring for loose conne...

Страница 36: ...reaker is between 195 and 264 VAC V4MB TCM High Voltage B Incoming line voltage is too high Ensure incoming system power is wired properly Verify voltage at each circuit breaker is between 195 and 264...

Страница 37: ...ast time the motor was turned off to reduce the chance of the motor overheating PROBLEM PROBLEM PROBLEM CAUSE CAUSE CAUSE SOLUTION SOLUTION SOLUTION Loose connections and or contactor CT01 is not clos...

Страница 38: ...llow for manual counterclockwise rotation of hydraulic pump Turn fan pulley by hand Verify oil flow by removing oil filter to see flow into filter manifold Reinstall oil filter Do NOT operate unit wit...

Страница 39: ...etermine which pump is losing pressure 2 Determine in which direction the pump has stalled by observing which directional icon is displayed on the ADM Home screen See Table 1 3 Repair the valve See pu...

Страница 40: ...if heater and PRESSURE RELIEF SPRAY valve SA or SB are plugged Clear Replace rupture disk with a new one do not replace with a pipe plug No pressure on one side Inadequate feed pump pressure Check fe...

Страница 41: ...are likely operating correctly proceed to step 2 If the indicating lights do not turn on proceed to step 6 2 Confirm the proximity switches 211 switch bracket 209 and switching plate 319 are firmly mo...

Страница 42: ...ver Left arrow labeled b Right arrow labeled a Last proximity switch triggered Right side proximity switch Left side proximity switch Terminals in directional valve energized Terminals associated with...

Страница 43: ...temperature Low supply voltage Verify line voltage Low line voltage significantly reduces power available to the hose heat system affecting longer hose lengths A and B setpoints too low Increase A an...

Страница 44: ...snug and that pins of connectors are clean Unplug and re plug FTS wires along length of hose cleaning off any debris Erratic hose temperature FTS not installed correctly FTS should be installed close...

Страница 45: ...es page 60 A and B temperature setpoints too low Increase A and B setpoints Hose designed to maintain temperature not increase temperature Hose temperature setpoint too low Check Increase if necessary...

Страница 46: ...for error codes Primary Heater s does not heat Signal failure from RTD Check ADM for error codes Confirm RTD cabling is properly connected and not damaged Replace RTD Dirty RTD connections Examine RT...

Страница 47: ...view of the sky Still establishing cellular connection Wait a few minutes for the unit to establish the connection Move system to a location with cellular service to establish cellular connection Has...

Страница 48: ...rocedure when you stop spraying and before cleaning checking or servicing equipment The Fusion AP gun is shown 1 Press to stop the pumps 2 Turn off all heat zones 3 Relieve pressure in gun and perform...

Страница 49: ...ess to park the Component A and Component B pumps The park operation is complete when green dot goes out Verify the park operation is complete before moving to next step 5 Press to deactivate the syst...

Страница 50: ...ters separately from heated hoses set PRESSURE RELIEF SPRAY valves SA SB to PRESSURE RELIEF CIRCULATION Flush through bleed lines N SA SB GA GB To flush entire system circulate through gun fluid manif...

Страница 51: ...e SA SB to Pressure Relif Circulation Route fluid to waste containers or supply tanks Ensure gauges GA GB drop to 0 psi SA SB GA GB Note Use drop cloth or rags to protect the Reactor and surrounding a...

Страница 52: ...When the reservoir is flushed clean fill with fresh lubricant 5 Thread the reservoir onto the cap assembly and place it in the bracket 6 Push the larger diameter supply ST tube approximately 1 3 of th...

Страница 53: ...Grade 46 synthetic BP Oil International Energol HLP HM ISO Grade 46 Carl Bechem GmbH Staroil HVI 46 Castrol Hyspin AWS 46 Chevron Rykon AW ISO 46 Exxon Humble Hydraulic H ISO Grade 46 Mobil Mobil DTE...

Страница 54: ...M See Electrical Schematics page 94 Close the electrical enclosure door 3 Remove mounting bolts from the bottom frame and move the system away from the wall Figure 2 4 Remove upper bolts 3 Tilt the el...

Страница 55: ...ion Installation Installation 1 Place the motor on the unit 2 Fasten the motor with bolts 3 Connect the wires using wire nuts See Electrical Schematics page 94 and the diagram inside the motor junctio...

Страница 56: ...rs 19 NOTICE NOTICE NOTICE To prevent damage to the overtemperature switch carefully remove the covers 3 Lift cover 132 and loosen the blue bracket 131 fasteners Lift the blue bracket 133 off of the f...

Страница 57: ...re cable with wire ties 5 Replace sensor and secure with wire ties Replace Replace Replace Pressure Pressure Pressure Transducers Transducers Transducers 1 Flush See Flushing page 50 2 See Shutdown pa...

Страница 58: ...que to 120 ft lbs 163 N m 8 Install the RTD 512 if removed earlier See Replace RTD page 59 9 Reconnect the wires inside the electrical enclosure Line Line Line Voltage Voltage Voltage The heater outpu...

Страница 59: ...8 Replace RTD cable 512 a Apply PTFE tape and thread sealant to male pipe threads and tighten RTD housing H into adapter 506 b Push in RTD 512 so tip contacts heater element 508 c Holding RTD 512 aga...

Страница 60: ...ins Pins Pins Resistance Resistance Resistance 3 to 1 See RTD Resistance vs Temperature page 61 3 to 4 See RTD Resistance vs Temperature page 61 1 to 4 0 2 0 4 ohms at the FTS each 50 ft cable adds 2...

Страница 61: ...imate Approximate Approximate Resistance Resistance Resistance Ohms Ohms Ohms Temperature Temperature Temperature C C C F F F 843 40 40 882 30 22 922 20 4 961 10 14 1000 0 32 1039 10 50 1078 20 68 111...

Страница 62: ...K D B ti18511a H Figure 9 Test Removal Test Removal Test Removal 1 Perform Shutdown page 49 2 Remove tape and protective covering from FTS Disconnect hose cable F 3 If FTS is not reading properly at...

Страница 63: ...e new circuit breaker Insert wires and tighten down all screws Table Table Table 4 4 4 H H H 30 30 30 H H H XP2 XP2 XP2 Circuit Circuit Circuit Breakers Breakers Breakers Ref Ref Ref Size Size Size Co...

Страница 64: ...rom TCM 2 Check transformer a Remove lower cover b Locate the two larger 6 AWG wires labeled 3 and 4 coming out of transformer Trace these wires back to TB31 Use an ohmmeter to test for continuity bet...

Страница 65: ...Protector Protector 1 Loosen connections on terminals 1 and 3 on CB13 See Electrical Schematics page 94 2 Loosen connections on input to power supply 805 on N and L connections See Electrical Schemat...

Страница 66: ...3 Replace HCM HCM HCM HCM Rotary Rotary Rotary Switch Switch Switch Positions Positions Positions 0 Reactor 2 H 30 1 Reactor 2 H 40 2 Reactor 2 H 50 3 Reactor 2 H XP2 4 Reactor 2 H XP3 Replace Replace...

Страница 67: ...rtioner Proportioner Parts Parts Parts page page page 68 68 68 Elite Elite Elite Kit Kit Kit see see see manual manual manual 3A3084 3A3084 3A3084 17H131 H 30 17H031 17F838 17H132 H 30 17H032 17F838 1...

Страница 68: ...on swiveling pipe threads 3 Ensure that the fan 9 direction arrow points away from the mounting panel 4 Install pulley 45 flush with motor shaft 43 5 Install pulley 44 overhung on pump shaft 27 by 18...

Страница 69: ...e sealant to all non swiveling pipe threads 4 Labels are from warning label 629 included in the Electrical Enclosure See Electrical Enclosure page 87 5 Apply single component thixotropic anaerobic sea...

Страница 70: ...Parts 1 Apply anaerobic pipe sealant to all non swiveling pipe threads 6 Apply high viscosity anaerobic sealant to threads 7 Fill reservoir 16 with hydraulic oil 70 334946C...

Страница 71: ...e sealant to all non swiveling pipe threads 4 Labels are from warning label 629 included in the Electrical Enclosure See Electrical Enclosure page 87 5 Apply single component thixotropic anaerobic sea...

Страница 72: ...et 1 1 1 16b 247771 GASKET inlet 1 1 1 16c 247777 TUBE inlet 1 1 1 16d 247770 TUBE return 1 1 1 16e 25D893 FILTER inlet 1 1 1 16f 255032 PLUG 1 1 1 16g 255021 FITTING straight 1 1 1 17 117556 FITTING...

Страница 73: ...in 10kw 1 55 17G600 TUBE fluid iso heater inlet 1 1 17G615 TUBE fluid iso heater out 10kw 1 56 17G601 TUBE fluid iso heater outlet 1 1 17G613 TUBE fluid res heater inlet 10kw 1 57 17G603 TUBE fluid r...

Страница 74: ...fts rtd single hose 1 1 1 103 C19843 SCREW cap sockethead 1 1 1 104 255716 KIT heater wire connector 1 105 C20487 FITTING nipple hex 2 2 2 106 114027 WASHER flat 8 8 8 107 RIVET pop 5 32 dia 8 8 8 10...

Страница 75: ...n pnh w ext tooth wash 4 4 4 143 SPACER nylon 1 4 in od 4 4 4 146 119865 SCREW mach hex serrated 4 4 4 148 LABEL A B 1 1 1 154 17B856 TERMINAL BLOCK 1 1 155 C19208 WASHER lock 1 1 156 111714 SCREW 1 1...

Страница 76: ...cap hex hd 20 20 20 20 20 20 20 20 16 247826 RESERVOIR assembly hydraulic 1 1 1 1 1 1 1 1 16a 247778 HOUSING inlet 1 1 1 1 1 1 1 1 16b 247771 GASKET inlet 1 1 1 1 1 1 1 1 16c 247777 TUBE inlet 1 1 1 1...

Страница 77: ...1 1 47 247853 ADJUSTER belt tensioner 1 1 1 1 1 1 1 1 48 111802 SCREW cap hex hd 2 2 2 2 2 2 2 2 49 247856 PULLEY fan 1 1 1 1 1 1 1 1 50 120087 SCREW set 1 4 x 1 2 2 2 2 2 2 2 2 2 51 803889 BELT ax46...

Страница 78: ...2 2 2 2 2 2 84 125943 NUT serrated flange 2 2 2 2 2 2 2 2 85 101032 BOLT machine 2 2 2 2 2 2 2 2 88 17G687 HARNESS overtemp reactor dual 1 1 1 1 1 1 1 1 91 121309 FITTING adapter sae orb x jic 2 2 2 2...

Страница 79: ...right 1 1 1 1 1 1 1 1 135 17G607 COVER heater left 1 1 1 1 1 1 1 1 136 BAR 55 gal chem meas B side 1 1 1 1 1 1 1 1 137 BAR 55 gal chem meas A side 1 1 1 1 1 1 1 1 138 17G686 HARNESS heater B 1 1 1 1...

Страница 80: ...pipe sealant to all non swiveling pipe threads 4 Remove cover from directional valve 207 and attach solenoid harness wires 225 See Electrical Schematics page 94 5 Fully seat pin 213 with a hammer and...

Страница 81: ...111800 SCREW cap hex hd 2 211 17G605 SENSOR proximity switch 2 212 M70430 SCREW set socket 1 4 28 x 19 2 213 296653 PIN clevis 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty...

Страница 82: ...306 295641 SEAL u cup 2 307 295642 RING back up 2 308 296643 RING wear 1 309 158776 PACKING o ring 2 310 295644 RING back up 2 311 295645 WIPER rod 2 312 296646 SEAL shaft 2 Ref Ref Ref Part Part Part...

Страница 83: ...102814 GAUGE press fluid 2 404 162453 FITTING 1 4 NPSM X 1 4 NPT 2 405 15M669 SENSOR pressure fluid outlet 2 406 247788 HANDLE red 1 407 247789 HANDLE blue 1 408 112309 NUT hex jam 2 411 117556 NIPPLE...

Страница 84: ...m 2 Torque to 23 ft lbs 31 N m 3 Apply thermal paste 4 Apply pipe sealant and PTFE tape to all non swiveling threads and threads without o rings 5 Apply lithium grease lubricant to o rings before asse...

Страница 85: ...scription Description 17G646 17G646 17G646 17G648 17G648 17G648 17G647 17G647 17G647 501 HEATER housing 1 1 1 502 124132 O RING 3 4 4 15H305 FITTING plug holow hex 1 3 16 sae 5 4 503 15H302 FITTING 1...

Страница 86: ...de 6 Orientate gauges vertically within assembly Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 901 118459 FITTING union swivel 3 4 in 4 902 16W714 MANIFOLD strainer inlet...

Страница 87: ...trical Electrical Electrical Enclosure Enclosure Enclosure W WL L E E 3 3 1 Install disconnect switch 609 so that up is ON and left is OFF 2 Mount fans 604 632 with arrows pointing towards the panel 3...

Страница 88: ...ROMMET rubber 1 1 1 617 GROMMET 1 75 id x 12 groove 2 2 2 618 127278 NUT keps hex 4 8 8 619 16W925 GASKET enclosure foam 2 2 2 620 16W926 GASKET enclosure foam 2 2 2 621 24R735 CABLE can power m12 fem...

Страница 89: ...f Ref Ref Part Part Part Description Description Description Qty Qty Qty 701 17G691 HARNESS breaker module 1 702 17G692 HARNESS hose out 1 703 MODULE din rail power supply 1 704 MODULE din rail circui...

Страница 90: ...V 1 806 255022 RELAY contactor 65A 3p 1 807 24R724 BLOCK terminal UT35 6 H H H 30 30 30 H H H XP2 XP2 XP2 System System System Circuit Circuit Circuit Breaker Breaker Breaker Module Module Module Ref...

Страница 91: ...ity Ref Ref Ref Part Part Part Description Description Description 200 240 200 240 200 240 V V V 350 415 350 415 350 415 V V V 701 17G691 HARNESS breaker module 1 1 702 17G692 HARNESS hose out 1 1 703...

Страница 92: ...17F837 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 1 ASSEMBLY transducer includes 1a and 1b 2 1a 624545 FITTING nipple pipe 2 1b 24U851 TRANSDUCER includes foam 2 2 16W...

Страница 93: ...6 255022 RELAY contactor 65A 3p 1 H H H 40 40 40 H H H 50 50 50 H H H XP3 XP3 XP3 System System System Circuit Circuit Circuit Breaker Breaker Breaker Module Module Module Ref Ref Ref Part Part Part D...

Страница 94: ...al part numbers ti26606b 17D775 TB04TB05TB06 TB07TB08TB09 24R725 Jumper 16U530 24R757 To TB31 80mm Enclosure Fan CB11 CB12 CB13 CB14 CB15 HOSE MOTOR A HEAT B HEAT TRANS CT01 POWER SUPPLY F12 F11 TB03...

Страница 95: ...Module Kits page 89 for additional part numbers 24R757 To TB31 17G650 120mm Enclosure Fan 80mm Enclosure Fan CB11 CB12 CB13 CB14 CB15 HOSE MOTOR A HEAT B HEAT TRANS CT01 POWER SUPPLY F12 F11 TB03 TB02...

Страница 96: ...Module Kits page 89 for additional part numbers 24R757 To TB31 17G650 120mm Enclosure Fan 80mm Enclosure Fan CB11 CB12 CB13 CB14 CB15 HOSE MOTOR A HEAT B HEAT TRANS CT01 POWER SUPPLY F12 F11 TB03 TB02...

Страница 97: ...upply 24R735 127068 A Pressure Transducer B Pressure Transducer Fluid Manifold B Inlet Pressure Temperature Transducer A Inlet Pressure Temperature Transducer WHITE ORANGE GREEN BLACK RED 17G670 9 1 1...

Страница 98: ...To ADM To Ground Bar To Ground Bar To Heated Hose 2 24W204 A RTD B RTD B HEATER A HEATER Transformer Fan 24R756 Hose Transformer 127290 127068 127068 TCM ti26607a 3 4 To Hose RTD 1 Locate near TCM 2...

Страница 99: ...r Seal Kit Pump 202 261852 H 40 Cylinder Seal Kit Pump 202 247581 H 30 and H 50 Cylinder Seal Kit Pump 202 261847 H XP2 and H XP3 Piston Seal Kit Pump 202 261845 H 40 Piston Seal Kit Pump 202 247579 H...

Страница 100: ...XP3 2 79 1 Fluid Fluid Fluid Inlets Inlets Inlets Component A ISO 3 4 npt f 300 psi maximum 3 4 npt f 2 07 MPa 20 7 bar maximum Component B RES 3 4 npt f 300 psi maximum 3 4 npt f 2 07 MPa 20 7 bar ma...

Страница 101: ...ty Capacity 3 5 gal 13 6 liters Recommended Recommended Recommended Hydraulic Hydraulic Hydraulic Fluid Fluid Fluid Citgo A W Hydraulic Oil ISO Grade 46 Sound Sound Sound Power Power Power per per per...

Страница 102: ...breach of warranty must be brought within two 2 years of the date of sale GRACO GRACO GRACO MAKES MAKES MAKES NO NO NO WARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL...