Installation
◆
Check Resistance
310633C
25
Check Resistance
Have a qualified electrician check resistance between
each ProMix™ II component and true earth ground. If
resistance is greater than 1 ohm, a different ground site
may be required. Do not operate the system until the
problem is corrected.
F
IG
. 26: Grounding
Key:
EasyKey™ Display
EasyKey™ Display ground terminal
Display Enclosure ground wire
Fluid Panel ground wire connection point
Fluid Panel ground wire
True Earth Ground - check your local code for requirements
Operator Station ground wire connection point
Operator Station ground wire
Gun Flush Box ground wire connection point
Gun Flush Box ground wire
Ground wires for the EasyKey™ Display, Smart
Fluid Panel, Operator Station, and Gun Flush Box
must all be connected to the same true earth
ground. See F
IG
. 26, page 25.
6
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
WARNING
To ensure proper grounding, resistance between Pro-
Mix™ II components and true earth ground must be
less than 1 ohm. Read warnings, page 6.