Related Manuals

Component Manuals in English

Equipment Approvals

Equipment approvals appear on the following labels 
which are attached to the Fluid Station and Power Sup-
ply Module. See F

IG

. 1 on page 4 for label locations.

Manual

Description

313882

ProMix 3KS Manual System Operation

313885

ProMix 3KS Automatic System Operation

313883

ProMix 3KS Repair-Parts

312775

ProMix 2KS Manual System Installation

312776

ProMix 2KS Manual System Operation

312777

ProMix 2KS Manual System Repair-Parts

312778

ProMix 2KS Automatic System Installation

312779

ProMix 2KS Automatic System Operation

312780

ProMix 2KS Automatic System 
Repair-Parts

312781

Fluid Mix Manifold

312782

Dispense Valve

312783

Color Change Valve Stacks

312787

Color Change Module Kit

312784

Gun Flush Box Kits

310745

Gun Air Shutoff Kit

312786

Dump Valve and Third Purge Valve Kits

312785

Network Communication Kits

308778

G3000/G3000HR Flow Meter

313599

Coriolis Flow Meter

313290

Floor Stand Kit

313542

Beacon Kit

313386

Basic Web Interface/Advanced Web 
Interface

406799

15V256 Automatic System Upgrade Kit

406800

15V825 Discrete I/O Board Kit

SERIES NO. MFG. YR.

PART NO.

AMPS

VOLTS

85-250 ~ 

2 AMPS MAX

POWER REQUIREMENTS

GRACO INC.
P.O. Box 1441
Minneapolis, MN 
55440 U.S.A.

II (2) G
[Ex ia] IIA
FM08ATEX0072

Intrinsically safe connections
for Class I, Div 1, Group D
Ta = -20°C to 50°C
Install per 258682

C

US

50/60 Hz

ProMix  3KS

®

Um: 250 V

GRACO INC.
P.O. Box 1441
Minneapolis, MN 
55440 U.S.A.

.7

7

MAX AIR WPR

MPa

bar

PSI

FLUID PANEL

ProMix  3KS

100

PART NO.

SERIES

SERIAL MFG. YR.

C

US

Intrinsically safe equipment
for Class I, Div 1, Group D, T3
Ta = -20°C to 50°C
Install per 289833

FM08ATEX0073
II 2 G
Ex ia IIA T3

®

.7

7

100

MAX AIR WPR

MPa

bar

PSI

MAX FLUID WPR

MPa

bar

PSI

PART NO.

SERIES

Read Instruction Manual

Warning: Substitution of components
may impair intrinsic safety.

SERIAL

ProMix

® 

3KS

Electronic Proportioner

MAX TEMP 50°C (122°F)

Intrinsically Safe (IS) System.  Install 
per IS Control Drawing No. 258682.
EasyKey Interface IS Associated
Apparatus for use in non hazardous
location, with IS Connection to Smart 
Fluid Plate IS
Apparatus for use in:
Class I, Division 1, Group D T3 C
Hazardous Locations

Intrinsically safe

equipment for Class I,

Div 1, Group D, T3

Ta = -20°C to 50°C

C

US

FM08ATEX0074
II 2 G
Ex ia IIA T3

GRACO INC.
P.O. Box 1441
Minneapolis, MN 
55440 U.S.A.

MFG. YR.

TI14376a

ATEX Certificate is listed here

ATEX Certificate is listed here

ATEX Certificate is listed here

TI14374a

TI14375a

Power Supply Module Label

Fluid Station Label

Power Supply Module and Fluid Station Label

Содержание ProMix 3KS

Страница 1: ...l use only Approved for use in explosive atmospheres except the EasyKey and 3KS Power Supply Module TI14543a See page 4 for model information including maximum working pressure Equipment approval labe...

Страница 2: ...uirements 20 Connect Main Power 20 Connect Power Supply Module to ProMix 3KS Fluid Station 21 Connect Booth Control to ProMix 3KS Fluid Station 21 Connect Color Change Module to ProMix 3KS Fluid Stati...

Страница 3: ...250 2 AMPS MAX POWER REQUIREMENTS GRACO INC P O Box 1441 Minneapolis MN 55440 U S A II 2 G Ex ia IIA FM08ATEX0072 Intrinsically safe connections for Class I Div 1 Group D Ta 20 C to 50 C Install per 2...

Страница 4: ...re 0 0 FIG 1 Identification Label 7 7 100 MAX AIR WPR MPa bar PSI MAX FLUID WPR MPa bar PSI PART NO SERIES Read Instruction Manual Warning Substitution of components may impair intrinsic safety SERIAL...

Страница 5: ...t C change option 0 and no flow control Optional with ProMix 2KS Base Unit 3000 psi 21 0 MPa 210 bar Meter Option 1 2 and 4 G3000 G3000HR or Solvent Meter 3000 psi 21 0 MPa 210 bar Meter Option 3 Cori...

Страница 6: ...SHOCK HAZARD This equipment must be grounded Improper grounding setup or usage of the system can cause electric shock Turn off and disconnect power at main switch before disconnecting any cables and b...

Страница 7: ...s away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicab...

Страница 8: ...of the ProMix 3KS Kit All other components are part of the ProMix 2KS System or are available as accessories FIG 2 Manual System Shown with G3000 Meters Booth Control and Color Catalyst Component C Ch...

Страница 9: ...flow meters and the 3K fluid manifold assembly Its control board manages all pro portioning functions 2K Fluid Manifold 2KM Pneumatically Operated Dose Valves for component A and B Purge Valves for s...

Страница 10: ...20 or 061 3 8 in fluid passages set K factor to 061 or 0 119 Color Change Valves ACV and Color Change Module CCM An optional component It is available as a color change valve stack for either low or h...

Страница 11: ...g of components is allowed only if high integrity equipotential system is realized between the points of bonding 4 Do not operate system with safety barrier cover removed 5 For ATEX install per EN 600...

Страница 12: ...e ments on page 11 WARNING Substitution of components may impair intrinsic safety For installation maintenance or opera tion instructions see instruction manual ADVERTISSEMENT La substitution de compo...

Страница 13: ...e compo nent C fluid supply line and the ProMix system A 100 mesh minimum fluid filter must be installed on the component C fluid supply line Wall Mounting 1 See Dimensions and Mounting Hole Layouts p...

Страница 14: ...ew Pro Mix 3KS upgrade board UB with J3 on the display board Press them together FIG 5 6 Secure the ProMix 3KS upgrade board UB with the screw E To avoid electric shock turn off EasyKey power before s...

Страница 15: ...Install the ProMix 3KS Upgrade Board 313881C 15 FIG 5 255767 Display Board Connectors RT1 J3 Upgrade Board Plug in Remove Screw E C TI12496a UB PS J4 on underside of upgrade board...

Страница 16: ...ly equipment Install an additional shutoff valve upstream of all air line accessories to isolate them for servicing Air line filter a 10 micron or better air filter is rec ommended to filter oil and w...

Страница 17: ...ply install filters dryers as needed NOTICE Use separate air supply lines for the following two connections to avoid contaminating the purge air line with fluid if the air purge valve and a check valv...

Страница 18: ...he component C supply line s Single component C system connect component supply line to the component C flow meter inlet Multiple component C system connect component C supply lines to the color chang...

Страница 19: ...ft 1 83 m fluid supply line from 2KS fluid manifold static mixer outlet to 1 4 npt m fitting Connect gun fluid supply line to 1 4 npt fluid outlet 1 2 1 2 FIG 8 Color Change Valves Air and Fluid Conn...

Страница 20: ...Module Install a bulkhead strain relief or conduit bulkhead through the Power Supply Module port See FIG 10 2 See FIG 9 and the System Electrical Schematic on page 36 for the L1 N and ground wiring c...

Страница 21: ...ee FIG 13 and FIG 15 Connect Color Change Module to ProMix 3KS Fluid Station NOTE Disconnect and discard the 3 ft 0 9 m gray cable supplied with the ProMix 2KS system connecting the color change modul...

Страница 22: ...on S1 TI15225a Table 2 3KS CAN Isolation Board Switch Settings Component Connector Diagnosis S1 J1 J2 If booth control is connected to J1 and color change module is connected to J2 set switch S1 to OF...

Страница 23: ...ttings See FIG 12 On the 2KS fluid station control board set switch S1 to ON down for all ProMix 3KS units FIG 12 255765 Fluid Station Control Board Set Switch S1 to ON down for all ProMix 3KS units S...

Страница 24: ...d See FIG 14 and FIG 15 The solenoid wiring cable is shipped attached to the ProMix 3KS Fluid Station Con nect the cable to the ProMix 2KS Fluid Station Board by threading it through the strain relief...

Страница 25: ...Apply labels supplied FIG 15 ProMix 3KS Cabling Connection Detail TI14702a Detail of ProMix 3KS Cable Connections 10 ft 3 0 m green color coded 6 ft 1 83 m yellow color coded 50 ft 15 2m yellow color...

Страница 26: ...olor Terminal Block Pin No Wire Color Pin No Red 1 Meter C Power Red J12 4 Black 2 Meter C Common Black J12 5 White 3 Meter C Signal White J12 6 Black 4 Not Used Black 5 Dose C Black J9 6 Green 6 Dose...

Страница 27: ...Electrical 313881C 27...

Страница 28: ...olor change board and the sole noids see the color change module electrical sche matic FIG 17 Table 4 Color Change Board Switch Settings Two Color Change Boards Color Change Board 1 Color Change Board...

Страница 29: ...Electrical 313881C 29 FIG 16 Color Change Board Switches S3 S6 S3 S4 S5 S6 OFF ON OFF ON Switch S3 S6 Positions J7 J11 TI13661a...

Страница 30: ...5 4 3 2 1 6 5 4 3 2 1 CLR 12 CAT 4 CAT 3 CAT 2 CAT 1 SOL CAT CLR 8 CLR 7 CLR 6 CLR 5 CLR 4 CLR 3 CLR 2 CLR 1 SOL CLR COLOR BOARD 2 COLORS 13 THRU 30 CLR 22 CLR 23 CLR 24 1 2 3 4 5 6 12VDC COM 12VDC C...

Страница 31: ...Electrical 313881C 31...

Страница 32: ...ect the meter cables as shown in the System Electrical Schematic Hazardous Area on page 38 Failure to properly connect the shield may cause incor rect signals Feed Pumps or Pressure Pots Connect a gro...

Страница 33: ...Module ground wire Part No 223547 Power Supply Module ground screw Power Supply Module ground wire 3KS Fluid Station ground screw 3KS Fluid Station ground wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Gun Flu...

Страница 34: ...E DOSE B VALVE CLOSE OPEN 5 32 TUBE 12 VDC GFB 1 VALVE OPTIONAL 5 32 TUBE A COLOR 1 COLOR 2 COLOR 3 COLOR 4 COLOR 5 COLOR 6 COLOR 7 COLOR 8 COLOR SOLVENT COLOR 9 COLOR 10 COLOR 11 COLOR 12 CATALYST 1...

Страница 35: ...19 OPTIONAL COLOR 20 OPTIONAL COLOR 21 OPTIONAL COLOR 22 OPTIONAL COLOR 23 OPTIONAL COLOR 24 OPTIONAL COLOR 25 OPTIONAL TO MANIFOLD 1 4 TUBE PURGE C VALVE DUMP C VALVE OPTIONAL 12 VDC 12 VDC AIR EXHAU...

Страница 36: ...NETWORK A WHT ORG RS485 NETWORK B ORG WHT RS485 NETWORK GROUND SHIELD FLOW CONTROL CAL BLK GUN TRIGGER WHT DIGITAL IN COMMON RED REMOTE STOP GRN ALARM RESET BRN ALARM OUTPUT BLU DIGITAL OUTPUT COMMON...

Страница 37: ...AREA TO FO OUT J4 BLU TO FO IN J6 BLK BARRIER BOARD 1 2 3 1 2 L1 N 85 250 VAC L1 N GND 85 250 VAC 1 2 3 J5 12VDC I S RED COM BLACK SHIELD 1 2 3 J4 24VDC OPEN COMMON 1 2 3 TERMINAL BLOCK 1 2 3 GND LUG...

Страница 38: ...grams 38 313881C System Electrical Schematic NOTE The electrical schematic illustrates all possible wiring expansions in a ProMix 3KS system Some compo nents shown are not included with all systems Ha...

Страница 39: ...81C 39 System Electrical Schematic NOTE The electrical schematic illustrates all possible wiring expansions in a ProMix 3KS system Some compo nents shown are not included with all systems Hazardous Ar...

Страница 40: ...unt Fluid Station TI14377a TI14382a Mounting plate only shown for clarity NOTE Height is shown from top of panel to fluid shutoff valves and does not include the effect of variable fluid integrator he...

Страница 41: ...6 7 167 6 11 5 292 1 8 0 x 10 75 203 2 x 273 1 0 3 7 6 22 2 10 1 EasyKey See ProMix 2KS installation manual 2KS Wall Panel See ProMix 2KS installation manual Booth Control See ProMix 2KS installation...

Страница 42: ...California Proposition 65 42 313881C...

Страница 43: ...two component solvent and waterborne paints polyurethanes epoxies acid catalyzed varnishes moisture sensitive isocyanates Viscosity range of fluid 20 5000 cps Fluid filtration user supplied 100 mesh...

Страница 44: ...manship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR I...

Отзывы: