Setup Screen 8
Use Setup Screen 8 (Configuration C0) to select the
averaging interval (in seconds) used to calculate the
dynamic arc. Press buttons T3/T4 to change the
setting. The default is sufficient for most applications.
See
for more information.
• Range is 0.01 – 1.00 by 0.01
• Default 0.10 (shown)
Setup Screen 9
Use Setup Screen 9 (Configuration C1) to select
the time (in seconds) for which arc detection is
disabled (blanking period) upon gun trigger. This
setting controls the time from when the electrostatics
are enabled until arc detection is enabled. Press
buttons T3/T4 to change the setting. User may wish
to increase this setting depending on gun starting
location.
See
for more information.
• Range is 0.0 – 2.0 by 0.1
• Default is 0.5 (shown)