Setup Screen 2
Use Setup Screen 2 (Parameter P02) to select the
remote interface (bUS) from which the controller
will accept external control. Press buttons T5/T6 to
change the setting.
The options are:
• 0 = oFF: Discrete I/O interface is disabled (local
operation).
• 1 = dio: Discrete I/O interface is enabled. This
selection is the default. See
,
for more information.
• 2 = CAn:Do not use this selection (if displayed).
Setup Screen 3
Use Setup Screen 3 (Parameter P03) to select the
input signal type for the discrete I/O interface analog
inputs (Ai). Press buttons T5/T6 to change the
setting. The options are:
• 0 = VoLt: Analog voltage inputs are voltage type
(0-10V). This selection is the default.
• 1 = CUrr: Analog current inputs are current type
(4-20mA).
This setting applies to Current Setpoint and Voltage
Setpoint analog inputs for the Discrete I/O interface.
See
, for more information.
36
333266D