Maintenance
36
334135B
Install Upgrade Token
This procedure applies to the Local Control Module
(LCM).
1.
Disconnect power to the module.
2.
Remove token access panel.
3.
Press firmly the token into the slot.
NOTE:
There is no preferred orientation of the token.
4.
Restore power to the module. The red LED will flash
rapidly to signal that software is loading. When the
red LED stops flashing, the software is done load-
ing.
5.
Disconnect the power to the module.
6.
Remove the token.
7.
Replace the token access panel.
8.
Restore power to the module.
9.
Verify new software versions on the
screen. Refer to
PKE 2903 found at www.graco.com for the latest
software version by utilizing the search box.
F
IG
. 10: Remove Access Panel