Cleanup
28
3A4603F Operation, Repair, Parts
Cleanup
1. Perform
2. Remove guard and SwitchTip from all guns.
3. Unscrew cap, remove filter. Assemble without filter.
4. Clean filter, guard and SwitchTip in flushing fluid.
5. Attach ground wire to true earth ground or plug unit
into grounded outlet.
Flush Drain Tube
6. Remove fluid intake and drain tube from paint, wipe
excess paint off outside.
7. Place siphon tube set in grounded metal pail
partially filled with flushing fluid. Use water for water
base paint and mineral spirits for oil-based paint.
8. To flush drain tube and pump turn prime valve down.
9. Turn pressure control to Fast Flush (ES1000), or 1/2
position (ES2000), and operate until the pump runs
steady and flushing fluid appears in the waste pail.