Pressure Relief Procedure
6
332230T
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Turn engine OFF.
2. Release pressure on bead tank to 0 psi (0 bar, 0
MPa). Turn pressure relief valve (8) to vertical
position and watch bead tank pressure gauge until
pressure reads 0 psi (0 bar, 0 MPa). Do not use
safety valve (3) to release pressure from bead tank.
3. Loosen wing nut (2) until it reaches end of threads.
If any remaining pressure is in bead tank, it will be
released through seal while wing nut secures lid to
hopper. Confirm pressure is at 0 psi (0 bar, 0 MPa)
and open lid.
4. Secure lid over opening and tighten wing nut until
lid is level with hopper.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
3
8
ti21075a
ti21081a
2
ti21077a
ti21080a
Содержание LineLazer 200DC