Troubleshooting
16
334627K
Check Module
Check the module operation to verify if the module has
failed and needs to be replaced.
1.
Visually check for the presence of glue in the weep
hole (W). See
Figure 11
.
NOTE:
If glue is present, the module needs to be
replaced. See
Replace Module
2.
Verify that the air pressure to the solenoid valve is
65-80 psi (0.44-0.55 MPa, 4.4-5.5 bar).
3.
Verify that there is air pressure to the motor, which
will verify that there is fluid pressure.
4.
Make sure the system is at the correct temperature.
5.
While looking in the weep hole, press the solenoid
valve manual override switch (M) to manually trigger
the applicator.
NOTE:
Look through the weep hole. If the rod moves,
the module is functioning properly. If the rod does not
move, the module needs to be replaced. See
Replace
Module
on page
6.
Remove the nozzle.
7.
Press the manual override switch to trigger the
module. If glue flows from the seat, the module is
functioning properly.
Check Nozzle and Module
Trigger the applicator without the nozzle to determine if
the nozzle of the module is clogged.
1.
Disable the applicator assembly. See
Before
Beginning Repair
on page
2.
Use a 1/2 in. wrench to loosen the nozzle and
remove it by hand.
3.
Connect the power and solenoid cable.
4.
Return the applicator back into operation.
5.
Trigger the applicator.
a.
If adhesive flows, clean the nozzle and reinstall
it on the module.
b.
If the adhesive does not flow, the module is
clogged and needs to be replaced. See
Replace Module
on page
F
IG
. 11
WLD
0
:
F
IG
. 12
WLD
=