Installation
309815T
9
Husky 1050 Wall Mount
1.
Be sure wall can support weight of pump, hoses,
and accessories, and can withstand stress during
operation.
2.
Position wall bracket (204) no more than 5 ft (1.52
m) above floor. Check that bracket is level. Attach to
wall, using screws long enough to keep bracket
from vibrating. See F
. 3.
3.
Connect swivel union (205) to pump inlet.
4.
Install bushing (3) in pump air inlet.
5.
Install pump (201) on bracket (204) securely, using
provided dampeners, washers, and lock nuts.
6.
Connect elbow (206) to top of riser tube kit (202).
7.
Connect suction hose (203) to elbow (206) and inlet
swivel (205).
8.
Follow steps 1-7, pages 5-6, to finish installation.
Standard 2:1 Kit
1.
Follow steps 1-3, page 5.
2.
Open drum bung hole. Screw bung adapter with
gasket into bung hole. See pump manual 311882.
3.
Install swivel fitting (1c) in pump fluid outlet. See
F
. 4.
4.
Connect hose (1b) between swivel fitting (1c) and
Reactor swivel inlet (D, see F
5.
Remove elbow and 2 in. bushing supplied with des-
iccant dryer (6, see F
. 1). Screw dryer 3/4 npt fit-
ting into vent of A component (ISO) drum.
6.
Follow steps 6-7, page 6, to finish installation.
F
IG
. 3. Husky 1050 Wall Mount
WLD
203
201
205
202
204
206
3
F
IG
. 4. Standard 2:1 Kit
1c
Bung
TI10281a
1a
adapter
1b