12
308981
Maintenance
Lubrication
The air valve is lubricated at the factory to operate with-
out additional lubrication. If you want to provide addi-
tional lubrication, remove the hose from the pump air
inlet and add two drops of machine oil to the air inlet
every 500 hours of operation or every month.
Flushing and Storage
Flush the pump to prevent the fluid you are pumping
from drying or freezing in the pump and damaging it.
Use a compatible solvent.
Always flush the pump and
relieve the pressure
before
you store it for any length of time.
Read
on page 11.
Tightening Threaded Connections
Before each use, check all hoses for wear or damage
and replace as necessary. Check to be sure all threaded
connections are tight and leak-free.
Check fasteners. Tighten or retorque as necessary.
Although pump use varies, a general guideline is to
retorque fasteners every two months. See
Preventive Maintenance Schedule
Establish a preventive maintenance schedule, based on
the pump’s service history. This is especially important
for prevention of spills or leakage due to diaphragm fail-
ure.
CAUTION
Do not over-lubricate the pump. Oil is exhausted
through the muffler, which could contaminate your fluid
supply or other equipment. Excessive lubrication can
also cause the pump to malfunction.