background image

Installation

3A2960A

9

F

IG

. 6

GLC 2200

External
Alarm

Low Level
Switch

Pump
Reservoir

Dual Line System

Cycle
Switch

Bi-flo
Valves

Lubrication Points

Vent
Line

Pump On/Off

Reverser

Содержание GLC 2200

Страница 1: ...For controlling and monitoring an automated lubrication system Not approved for use in explosive atmospheres or hazardous locations Model 24N468 Important Safety Instructions Read all warnings and in...

Страница 2: ...the maximum working Pressure or temperature rating of the lowest rated system com ponent See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted p...

Страница 3: ...nd an audible alarm also sounds RIGHT Direction Arrow MANUAL RUN ENTER G In SETUP MODE saves entry moves cursor in display one field to the right or to the next setup step In RUN MODE activates the pu...

Страница 4: ...B Filter Regulator Lubricator Assembly B1 Filter B2 Regulator B3 Lubricator C Air Solenoid Valve D Pump Module E Ignition Switch F High Pressure Lubricant Supply Lines G Injector Banks H Lubrication...

Страница 5: ...les FIG 3 a Use two screws not provided to secure junction box to mounting surface AUTOMATIC SYSTEM ACTIVATION HAZARD Unexpected activation of the system could result in seri ous injury including skin...

Страница 6: ...to determine the Required System Configuration Sensor Configuration and Wiring Diagram to use to setup your system Table 4 shows additional optional setup configurations Table 1 System Configurations...

Страница 7: ...Installation 3A2960A 7 System Configuration FIG 4 GLC 2200 Low Level Switch Pump Reservoir Injector System Pressure Switch Injectors Lubrication Points Vent Line Pump On Off External Alarm...

Страница 8: ...Installation 8 3A2960A FIG 5 GLC 2200 Low Level Switch Pump Reservoir Master Divider Valve Secondary Divider Valves Cycle Switch Series Progressive System Pump On Off External Alarm...

Страница 9: ...Installation 3A2960A 9 FIG 6 GLC 2200 External Alarm Low Level Switch Pump Reservoir Dual Line System Cycle Switch Bi flo Valves Lubrication Points Vent Line Pump On Off Reverser...

Страница 10: ...Installation 10 3A2960A Sensor Wiring Configurations DRY CONTACT SWITCH SOURCE SWITCH 2 or 3 Wire Type FIG 7 4 9 FIG 8 4 9 VDC...

Страница 11: ...odes of GLC2200 Operation Wiring Key Connector Identification Label FIG 9 1 2 3 4 5 6 7 8 9 10 M 9A Fuse Pin Description 1 Pump 2 Alarm 3 Low Level 4 Pressure Cycle Switch 5 Voltage Input 6 Pump 7 Ala...

Страница 12: ...ock in the selec tion 3 Pressure control is an ON OFF selection only Not additional pro gramming is required Cycle Mode on CY ON Setup 1 Use the UP or DOWN ARROW to cycle through the on Pr on CY or on...

Страница 13: ...S field value is 59 The controller automatically switches to the OFF TIME SETUP MODE Programming OFF TIME Duration After setting the parameters for either Pressure P Cycle C or Time T ON Modes the OFF...

Страница 14: ...dicates the amount of time remaining in the pump OFF cycle counting down the Pump OFF time value see Programming OFF Time Duration page 13 The pump output is disabled during the Pump OFF time The Time...

Страница 15: ...time value see Programming OFF Time Duration page 13 The Time OFF LED illuminates and the pump output is disabled during the Pump OFF time Pump OFF time is shown in HH MM hours minutes or MM SS if the...

Страница 16: ...pen level switch closes upon low level Outputs Pump control Pump Control Voltage Power Source Voltage Power Source Max Switching Voltage 30 VDC Max Switching Current 9A DC Alarm normally open Voltage...

Страница 17: ...Dimensions 3A2960A 17 Dimensions Mounting Hole Layout 2 75 in 69 85 mm 5 5 in 139 7 mm 1 23 in 31 24 mm 1 63 in 41 4 mm 4 95 in 125 8 mm...

Страница 18: ...rtation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor an...