![Graco Geo Blaster GB1200 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/graco/geo-blaster-gb1200/geo-blaster-gb1200_operation-and-parts_2252667010.webp)
Pressure Relief Procedure
10
3A4167C
Pressure Relief Procedure
1.
Close the abrasive ball valve (P).
2.
Close the compressor supply air valve, then turn the
compressor off.
3.
Engage the blast control switch to relieve pressure
in the system.
4.
Verify that the supply air pressure gauge (L) reads
0 psi. Then disconnect the air inlet hose from the
system.
5.
Turn selector valve (K) to the OFF position.
6.
Open pot dump valve (N) to depressurize the blast
pot. Ensure pot pressure gauge (G) and supply air
pressure gauge (L) read 0 psi.
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as splashing fluid, follow
the Pressure Relief Procedure when instructed.
P
L
K
N
Содержание Geo Blaster GB1200
Страница 25: ...Parts 3A4167C 25 Control Panel Components upper left...
Страница 27: ...Parts 3A4167C 27 Control Panel Components lower left...
Страница 29: ...Parts 3A4167C 29 Control Panel Components lower right...
Страница 31: ...Parts 3A4167C 31 Control Panel Components upper right Rear View of Item 48...
Страница 33: ...Parts 3A4167C 33 Control Panel Components rear...
Страница 35: ...Parts 3A4167C 35 Water Valve and Pressure Relief Valve Components...
Страница 37: ...Parts 3A4167C 37 Air Valve Components...
Страница 39: ...Parts 3A4167C 39 Water Valve and Filter Components...
Страница 42: ...Parts 42 3A4167C Water Pump Components...
Страница 53: ...Technical Data 3A4167C 53...