Screen Identification
332078C
27
Screen 4
Icon
Description
Both material pressures are being monitored during the refill and dispense cycles of the
machine. If the one component material pressure drops below the other component material
pressure by X amount, the machine will alert the user.
This is the amount of time before the alarm is checked after the refill done bit activates. It
allows the data in the analog unit to stabilize prior to checking for a fault.