Motor Replacement
333126A
35
Motor Replacement
FinishPro II 395
See Wiring Diagram, page 36.
Removal
1. Disconnect power.
2.
Relieve pressure
, page 11.
3. Remove pump (41);
Displacement Pump
Replacement
, page 18
4. Remove drive housing (42);
Drive Housing
Replacement
, page 20.
5. Remove screws (12) from cover (50).
6. Disconnect all leads from board (49). Remove
screws (6) and board.
7. Remove screws (47) and control box (48).
8. Remove screws (47) and manifold (15).
9. Remove screws (47) and motor (54) from frame
(59).
Installation
1. Install new motor (54) on frame (59) with screws
(47).
2. Install manifold (15) with screws (47).
3. Install control housing (48) with screws (47).
4. Install board (49) with screws (6). Connect all leads
to board. See wiring diagram for your sprayer model
on page 36.
5. Install drive housing (42);
Drive Housing Replace-
ment
, page 20.
6. Install pump (41);
Displacement Pump Replace-
ment
, page 18.
NOTICE
Do not drop gear cluster (44) and (40) when removing
from drive housing (42). Gear cluster may stay
engaged in motor front end bell or drive housing.
48
12
50
49
6
47
15
47
47
54
59
ti9605a
Содержание FinishPro II 395
Страница 7: ...Notes 333126A 7 Notes ...