Troubleshooting
30
334730F
Electrical
Symptom: Sprayer does not run, stops
running, or will not shut off.
Perform
1.
Plug sprayer into correct voltage,
grounded outlet.
2.
Set the SELECTOR switch to
OFF
wait
30 seconds and then set to
AIRLESS
(this ensures sprayer is in normal run
mode).
3.
Turn pressure control knob clockwise
1/2 turn.
4.
View digital display or remove control
box cover to view control board status
light. To determine which code (or any
other code besides voltage supply) refer
to the control board status light. Set the
SELECTOR switch to
OFF
, remove the
control cover then set SELECTOR
switch to
AIRLESS
. Observe the status
light. Blinking LED total count equals the
error code (for example: two blinks
equals CODE 02).
Keep clear of electrical and moving parts
during troubleshooting procedures. To
avoid electrical shock hazards when
covers are removed for troubleshooting,
wait 7 seconds after disconnecting power
cord for stored electricity to dissipate.
Problem
What to Check
How to check
Sprayer does not run at all
AND
Display is blank
OR
Control board status light
never lights
See flow chart, page 36.
Sprayer does not shut off
AND
Display shows E=02
OR
Control board status light
blinks 2 times repeatedly
Control board.
Replace control board.