Installation
10
3A6586D
Connect Power
Letters in parenthesis are used in this section for refer-
ence to callouts in the
Component Identification
sec-
.
1.
Cut power cord wires to the following lengths:
•
Ground wire - 6.5 inches (16.5 cm)
•
Power wires - 3.0 inches (7.6 cm)
•
Add ferrules as necessary. See
Figure 3
.
2.
Remove the four screws to separate the junction
box cover and disconnect switch (J) from the junc-
tion box (F) on the electric driver.
NOTE:
Inside the junction box, power wires to the driver
are connected to terminals 3L2 and 5L3 on the discon-
nect block. Refer to
Figure 5
for the terminal locations.
3.
Insert the power cord through the cord grip and into
the junction box.
4.
Refer to
Figure 5
and connect the wires from the
power cord into terminals 4T2 and 6T3. Each wire
can be connected to either terminal.
5.
Attach the ground wire to one of the two ground ter-
minals inside the junction box as shown in
Figure 6
.
All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.
F
IG
. 3: Power Cord
F
IG
. 4: Remove Junction Box Cover
LQ
LQ
F
J
F
IG
. 5: Terminal Connections
F
IG
. 6: Connect Power
/
/
/
7
7
7
Disconnect
Block
Incoming
Power
Power to
Driver
For clarity, power wires to
the driver are not shown
Cord Grip
Содержание E-Flo SP