Operation
333587B
39
Tandem Run Screen
1.
Toggles between two modes of control: Local and
Remote. See
Control Modes
on page
.
2.
Select to enter or exit the editing mode for the
screen.
3.
Displays the current pump pressure.
4.
Shows the pump currently selected as green.
5.
Shows the status of the Platen valve used during
pump depressurization. Green is on, gray is off.
6.
Low material level and empty material level
indicators. Shows as red when low or empty. See
Low Level and Empty Level Indicators
on page
.
7.
Displays the current dispense valve pressure.
8.
Used to run beads manually. This is only available
when the system is in Local mode. See
Manual
Pump Operation
on page
.
9.
Select to enter or exit drum depressurization mode.
See
Depressurization Mode
on page
.
10. Select to enter or exit dispense valve
depressurization mode. See
Depressurization
Mode
11. Select to enter or exit priming mode. See
Priming
Mode
.
12. Shows the status of the dispense valve. Green is on,
gray is off.
13. Displays the current flow rate.
14. Displays the Actual amount of material.
15. Shows the Style identification number that is
currently in use. See
Style Screen 1 - Style
Definition
.
16. Displays the name of the style that you have
assigned. See
Style Screen 1 - Style Definition
on
17. Toggles between Pump 1 and Pump 2. See item 4.
18. Displays the size of the pump.
19. Displays the current mode of control (Local or
Remote). See item 1.
NOTE:
The pump and material line show animated
operation and material flow when dispensing.
1
7
6
18
4
3
2
8
11
10
9
16
15
14
13
12
17
5
19