![Graco E-flo iQ 26B543 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/graco/e-flo-iq-26b543/e-flo-iq-26b543_installation-parts_2251280043.webp)
Troubleshooting
3A8217A
43
Troubleshooting
1. Follow
checking or repairing the Ram, Pump, or Platen.
2. Check all possible problems and causes before
disassembling the Ram, Pump, or Platen.
NOTE:
Refer to Supply Unit Operation manual for
descriptions of ADM diagnostic codes.
NOTE:
Refer to your Pump package manual for Pump
troubleshooting.
Supply Systems Troubleshooting
Problem
Cause
Solution
System will not turn ON.
No power to unit.
Check main power breaker is turned
ON.
Check power cord is connected.
Ram will not raise or lower.
Closed air valve or clogged air line.
Open, clear.
Not enough air pressure.
Increase.
Worn or damaged piston.
Replace. See
Hand valve closed or clogged.
Open, clear.
Ram raises and lowers too fast.
Air pressure is too high.
Decrease.
Air leaks around cylinder rod.
Worn rod seal.
Replace. See
Fluid squeezes past ram plate wip
-
ers.
Air pressure too high.
Decrease.
Worn or damaged wipers.
Replace. See
on page 41.
Pump will not prime properly or
pumps air.
Not enough pressure.
Increase pressure setting.
Worn or damaged piston.
Replace. See Pump manual.
Hand valve closed or clogged.
Open, clear. See
on page 41.
Hand valve is dirty, worn, or dam
-
aged.
Clean, service.
Air assist valve will not hold drum
down or push plate up.
Closed air valve or clogged air line.
Open, clear. See
on page 41.
Not enough air pressure.
Increase.
Valve passage clogged.
Clean. See
on
page 41.
Содержание E-flo iQ 26B543
Страница 73: ...Wiring Diagrams 3A8217A 73 Wiring Diagrams...
Страница 74: ...Wiring Diagrams 74 3A8217A...
Страница 75: ...Wiring Diagrams 3A8217A 75...
Страница 76: ...Wiring Diagrams 76 3A8217A...
Страница 77: ...Wiring Diagrams 3A8217A 77...
Страница 78: ...Wiring Diagrams 78 3A8217A...