![Graco E-flo iQ 26B543 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/graco/e-flo-iq-26b543/e-flo-iq-26b543_installation-parts_2251280023.webp)
Installation
3A8217A
23
Power Requirements
Each iQ Ram Supply Unit requires a dedicated circuit
protected with a circuit breaker.
Connect Power
1. Turn the Disconnect Switch (AZ) OFF.
2. Loosen the screws and remove the cover (318) on
the Power Junction Box (AJ).
3. Loosen the screws and remove the cover (350) on
the Heat Control Box (AX).
4. Insert the electrical cord through the electrical
enclosure strain relief bushing (SR).
5. Attach insulated ferrules to the end of each wire.
6. Connect the ground wire to the ground lugs (GL).
7. Connect power wires to the Disconnect Switch (AZ)
as shown below.
NOTE:
Use a flat-head or Pozidriv screwdriver to tighten
the terminals to 7-10 in-lb (0.8-1.1 N•m).
8. Tighten the strain relief bushing (SR) around the
electrical cord.
9. Attach the Heat Control Box cover (350) and the
Power Junction Box cover (318).
Voltage
Phase
Hz
Current
200-240 VAC
1
50/60
60 A
200-240 VAC
3 (
∆
)
50/60
38 A
380-420 VAC
3 (Y)
50/60
38 A
NOTICE
To avoid equipment damage, route and secure a
power cord that is long enough to allow the full range
of movement for the Ram.
F
IG
. 13
SR
350
GL
AZ
318
ti31214a
Содержание E-flo iQ 26B543