Setup
Setup
Setup Screen
Screen
Screen 19
19
19
Use this screen to enable or disable the run/stop
switch and auto restart.
Figure 26 Setup Screen 19
Setup
Setup
Setup Screen
Screen
Screen 19
19
19 Key
Key
Key
Enable or disable the run/stop
switch. The default setting is
disabled. See Run/Stop Switch Kit
in
.
When enabled, this configuration allows
the run/stop switch to pause the pump
while in a profile. When the run/stop
switch is active, the following pop-up
appears:
Disable the remote start function over
modbus.
When enabled along with the run/stop
switch, you must toggle the run/stop
switch when going from profile 0
(stopped) to run before the pump can
start. When the run/stop switch is active,
the following pop-up appears:
Enable or disable auto restart. The
default setting is disabled. If enabled, the
unit resumes operation at the profile that
was set before the unit was turned off.
Setup
Setup
Setup Screen
Screen
Screen 20
20
20
Use this screen to set the units for pressure, totals,
and flow.
Figure 27 Setup Screen 20
Setup
Setup
Setup Screen
Screen
Screen 20
20
20 Key
Key
Key
Select the pressure units:
• psi
• bar (default)
• MPa
Select the volume units:
• liters (default)
• gallons
• cc
Select the flow rate units:
• L/min (default)
• gpm
• cc/min
• oz/min
• cycles/min
Select the system mode (single or x2).
If you are in single mode but connected
to x2 or in x2 mode but connected to
single, error code WNNX appears.
3A2527H