Setup
Setup
Setup Screen
Screen
Screen 2
2
2
Use this screen to set the maximum, target, and
minimum force/fluid pressure for a selected pump
and profile. In force/pressure mode, you can set
a target force/fluid pressure. In flow mode, you
can set a maximum force/fluid pressure. In either
force/pressure or flow mode, you can set a minimum
pressure. See
, to specify
how the system will respond if the pump begins to
operate outside of the set boundaries.
Figure 12 Setup Screen 2
Setup
Setup
Setup Screen
Screen
Screen 2
2
2 Key
Key
Key
For systems with multiple pumps and
one display, select the pump (1 to 8)
from the menu.
NOTE: Three phase systems do not
support multiple pumps.
Select the profile (1 to 4) from the menu.
In flow mode, set the maximum pump
fluid force/pressure, as a percentage of
the maximum pressure of your pump.
This field is not used in pressure mode.
NOTE: If the profile does not have a
maximum pressure setting, the motor will
not run and error code WSCX appears.
In force/pressure mode, set the force/fluid
pressure target as a percentage of the
maximum pressure of your pump. This
field is not used in flow mode.
NOTE: If closed loop pressure is
enabled, the target pressure is displayed
as a pressure value (psi, bar, MPa) rather
than a percentage of maximum pressure.
See
Setup Screens 8 and 9, page 16
to
enable closed loop pressure control.
Optionally, set a minimum pump
force/fluid pressure, as a percentage of
the maximum force/fluid pressure of your
pump.
This softkey is disabled by default, and
only appears if the Profile
Profile
Profile Lock
Lock
Lock box is
checked on
.
Press to activate the profile that you just
edited.
Setup
Setup
Setup Screen
Screen
Screen 3
3
3
Use this screen to set your flow rate settings for a
selected pump and profile. In pressure mode, you
will set a maximum flow rate. In flow mode, you will
set a target flow rate. In either pressure or flow mode,
a minimum flow rate may be set. See Setup Screen
4 to specify how the system will respond if the pump
begins to operate outside of the set boundaries.
NOTE:
NOTE:
NOTE: With flow rate units of cc/min, the maximum
value that can be displayed is 9999. If the field
displays ####, the saved value is out of range. Go
to
and change the flow
rate to a larger unit. Return to this screen and reduce
the setting to a lower value that will be within the
display’s range, then reset the flow rate units to
cc/min.
Figure 13 Setup Screen 3
Setup
Setup
Setup Screen
Screen
Screen 3
3
3 Key
Key
Key
For systems with multiple pumps and
one display, select the pump (1 to 8)
from the menu.
NOTE: Three phase systems do not
support multiple pumps.
Select the profile (1 to 4) from the menu.
In flow mode, set a target flow rate. This
field is not used in pressure mode.
In pressure mode, set the maximum flow
rate. The software calculates the number
of pump cycles needed to achieve that
flow rate. This field is not used in flow
mode.
NOTE: If the profile does not have a
maximum flow rate setting, the motor will
not run and error code WSC_ appears.
Optionally, set a minimum flow rate.
This softkey is disabled by default, and
only appears if the Profile
Profile
Profile Lock
Lock
Lock box is
checked on
.
Press to activate the profile that you just
edited.
3A2527H
13