Remote DataTrak Operation
12
334222B
Prime Mode
1. Press
to enter Prime Mode screen. The Prime
symbol (PS) will appear in the display and the LED
(LE, F
. 2) will flash.
2. While in Prime Mode, the job total counter (JT) is
blank and will not count. However, the maintenance
counter (MC) will continue to decrement.
3. When a new drum is installed, press and hold
while in Prime Mode to reset the drum volume
remaining (DV) to the drum fill volume (DF).
4. To exit Prime Mode, press
. The Prime symbol
will disappear and the LED will stop flashing; the
screen will return to Run Mode (F
5. To enter Setup Mode, press and hold
for 3 sec-
onds.
Setup Mode
NOTE:
If a key is not pressed within one minute of
entering a setup screen, the system will return to Run
Mode (F
. 2. Press and hold
for 3 seconds.
•
If a password has not been assigned (set to ‘0000’),
the system will go directly to Setup screen 1.
Password Screen
If a password has been assigned (not set to ‘0000’), the
Password screen will appear (F
. 6). Enter the pass-
word to access the Setup screens.
1. To enter a password, press
to enter edit mode.
2. Once in edit mode, press
to scroll through dig-
its.
3. Press
to select the correct digit and move on to
the next.
4. When password is correct, press
on the right-
most digit to submit the password.
Setup Screen 1
Use Setup screen 1 to set runaway cycle rate (RS),
enable/disable runaway protection (RT), select pump
volume per cycle (PV), select flow rate units (FR), enter
drum size (DS), and enter drum fill volume (DF). See
F
1. Press
to toggle from field to field through the
screen.
F
IG
. 5: Prime Mode Screen
JT
MC
PS
F
IG
. 6: Password Screen