Installation
309550ZAP
15
Installation
Grounding
Spray gun:
Ground through connection to a properly
grounded fluid hose and pump.
Proportioner:
Follow the instructions in your
proportioner manual.
Setup
1. Close fluid valves A and B.
2. Connect A (ISO) and B (RESIN) fluid hoses to fluid
manifold.
3. Engage piston safety lock (L). See
4. Connect gun air whip hose (V) and air valve (W*) to
main air hose. Attach fluid manifold (M) to gun.
*
Air Valve (W) is not included with spatter pattern spray
gun.
5. Connect air line quick coupler (D). Turn on air. Open
air valve (W*). Air should flow from nozzle (N).
6. Disengage piston safety lock (L). See
7. Trigger gun to check for full mix chamber travel.
Front of air cap (C) should be approximately flush
with front retaining ring (U).
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
ti2411a
A (ISO)
B (RESIN)
TI2417A
TI2409A
L
W*
V
M
TI2554A
D
W*
N
TI2414-1A
TI2410A
L
C
U
TI2414-1A