Troubleshooting
Problem
Cause
Solution
No power received from DC power
supply.
Defective power supply.
Check circuit breaker. Check power
supply. Replace power supply.
No power to MCM, heat zones, or
tanks.
Circuit breaker is tripping.
Check circuit breaker for tripping and
defects. Diagnose cause of circuit
breaker tripping before resetting it.
Replace defective parts if required.