Setup
3A5278B
11
CGM I/O Data Map
Outputs from PLC; Inputs to Graco XM
Inputs to PLC; Outputs from Graco XM
Signal
Data Type
BYTE
Pump On Off Control
Integer
BYTES 0-1
Operation Mode Control
Integer
BYTES 2-3
Volume Ratio Target Ctrl
Integer
BYTES 4-5
Reset Alarms
Integer
BYTES 6-7
Reset Batch Totalizers
Integer
BYTES 8-9
Reset Potlife Time
Integer
BYTES 10-11
Set Job Number
Integer
BYTES 12-13
Spare Output 1
Integer
BYTES 14-15
Spare Output 2
Integer
BYTES 16-17
Spare Output 3
Integer
BYTES 18-19
Signal
Data Type
BYTE
Pump On Off
Integer
BYTES 0-1
Operation Mode
Integer
BYTES 2-3
Target Ratio
Integer
BYTES 4-5
Actual Ratio
Integer
BYTES 6-7
Event Code
Integer
BYTES 8-11
Temperature A
Integer
BYTES 12-13
Temperature B
Integer
BYTES 14-15
Pressure A
Integer
BYTES 16-17
Pressure B
Integer
BYTES 18-19
Flow Rate A
Integer
BYTES 20-21
Flow Rate B
Integer
BYTES 22-23
Batch Total A
Integer
BYTES 24-25
Batch Total B
Integer
BYTES 26-27
System in Weight Mode
Integer
BYTES 28-29
Temperature Units
Integer
BYTES 30-31
Pressure Units
Integer
BYTES 32-33
Volume Units
Integer
BYTES 34-35
Weight Units
Integer
BYTES 36-37
Potlife Timer Enable
Integer
BYTES 38-39
Potlife Timer
Integer
BYTES 40-41
Job Number
Integer
BYTES 42-43
Voltage System DC
Integer
BYTES 44-45
Spare Input 1
Integer
BYTES 46-47
Spare Input 2
Integer
BYTES 48-49
Spare Input 3
Integer
BYTES 50-51
Spare Input 4
Integer
BYTES 52-53
Spare Input 5
Integer
BYTES 54-55
Spare Input 6
Integer
BYTES 56-57
Spare Input 7
Integer
BYTES 58-59