Installation
12
3A5354B
Install/Adjust Drum Low Level
Switch
1. Verify the power is off.
2. Install the low level switch (S) onto the air motor
bracket (J) with two M5 washers and screws (MS).
3. Install the position bar (T) onto the air motor bracket
with two M20 nuts (M20).
4. Use a cable (CBL) to connect the low level switch
onto the control board (J4 connector).
5. Turn the main power switch (MP) to the ON position,
then press the power button to turn on the ADM.
6. Adjust the position bar height by threading at the
desired level (low or empty).
7. Check the low level switch function by lowering the
ram and letting the position bar hit the switch. Check
to make sure the light tower signal is red for the low
level alarm.
Light Tower Accessory
If the light tower kit (25C662) flashes red, there is a low
level alarm.
F
IG
. 9
M20
CBL
MS
S
J
T
F
IG
. 10: J4 Connector
J4 Connector