Troubleshooting
Troubleshooting
See Errors, page 72 for information about errors that
can occur on the system.
See Troubleshooting, page 53 for the ten most
recent errors that have occurred on the system. See
Troubleshoot Errors, page 73 to diagnose errors that
have occurred on the system.
See Error Codes and Troubleshooting for error
codes, possible causes, and solutions.
Error Codes and Troubleshooting
See Reactor repair manual for non-error based
troubleshooting.
Note
Error codes are stored in the error log and
displayed on the Error and Troubleshooting
screens on the ADM.
Error
Code
Error
Location
Type
Name
Cause
Solution
Loose or bad
connection.
Check wiring between
MCM and motor.
Motor brushes
completely worn down.
Check motor brushes and
replace if needed.
A1N1 MCM
ALARM
No Motor Current
Bad MCM.
Replace MCM. See
System Repair manual.
Wiring problem.
Check wiring between
HPTCM and contactor.
Look for shorted wire
between HPTCM and
contactor terminals A1 and
A2.
A4CH Hose
ALARM
High Relay
Current Hose
Shorted contactor.
Measure resistance
between A1 and A2
terminals. The resistance
should be about 289Ω.
If contactor is measuring
less than 100Ω, then the
contactor is shorted and
should be replaced.
74
3A1705E
Содержание 259079
Страница 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Страница 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Страница 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Страница 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Страница 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Страница 97: ...Notes Notes 3A1705E 97...