Pump
3A5082G
19
NOTE:
The reservoir air vent (P), located in rear of
reservoir, should not be used as an overfill
port/indicator.
4.
When the grease has reached the max fill line (F
21), remove the fill hose and replace the dust cap
(26) over the inlet fitting (25).
Priming
NOTE:
It is not necessary to prime the pump every time
the pump is filled with lubricant.
The pump only requires priming the first time it is used
or if it is allowed to run dry.
1.
Loosen the pump outlet fitting (F
NOTE:
When loosening pump outlet fitting, do NOT
loosen banjo bolt (A).
2.
Only run pump until air is no longer dispensed with
the lubricant (lu) coming out of outlet fitting (F
3.
Tighten pump element fitting using two wrenches
working in opposite directions.
F
IG
. 22
F
IG
. 23
P
26
F
IG
. 24
F
IG
. 25
outlet fitting
A
lu
Содержание 24Z660
Страница 7: ...Typical System Installation 3A5082G 7 FIG 4 ...
Страница 11: ...Pump 3A5082G 11 Pump Dimensions FIG 7 ...
Страница 13: ...Pump 3A5082G 13 Mounting Bracket and Pump Dimensions FIG 9 ...
Страница 67: ...Notes 3A5082G 67 Notes ...