Graco 24R021 Скачать руководство пользователя страница 3

Warnings

332198C

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific 
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where 
applicable. 

WARNING

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or 
swallowed.

Read MSDSs to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is 
not limited to:

Protective eyewear, and hearing protection. 

Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer

+

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical 
treatment.

Do not point dispensing device at anyone or at any part of the body.

Do not put your hand over the fluid outlet.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or 
servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent 
fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static arc). 

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they 
are antistatic or conductive.

Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment 
until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

Содержание 24R021

Страница 1: ...ds of non abrasive material For professional use only Not approved for use in European explosive atmosphere locations Model 24R021 2000 psi 14 MPa 137 bar Maximum Fluid Working Pressure Important Safe...

Страница 2: ...Operation 8 Prime 8 Pressure Balance the Gun 8 Ratio Checking 9 Install Disposable Static Mixer 9 Dispense 9 Pressure Relief Procedure 10 Daily Shutdown 10 Flushing 10 Install Restrictors or Plugs 11...

Страница 3: ...om dispensing device hose leaks or ruptured components will pierce skin This may look like just a cut but it is a serious injury that can result in amputation Get immediate surgical treatment Do not p...

Страница 4: ...ts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you...

Страница 5: ...by providing sufficient ventila tion in the work area If sufficient ventilation is not available a supplied air respirator is required for everyone in the work area To prevent contact with isocyanate...

Страница 6: ...rials flush the equipment multiple times to ensure it is thoroughly clean Always clean the fluid inlet strainers after flushing Check with your material manufacturer for chemi cal compatibility When c...

Страница 7: ...blue for component B RES Red ISO usually is connected to the left side of the valve as viewed from the back of the gun 5 Perform Prime procedure page 8 GROUNDING The equipment must be grounded to red...

Страница 8: ...ntinue to next step If not pressures are sufficiently balanced 4 If pressures are more than 25 apart replace one or both plugs or restrictors with a different restrictor size NOTE An extra 0 032 in re...

Страница 9: ...gun has not yet been pressure balanced per form Pressure Balance the Gun procedure on page 8 3 If the fluid in the static mixer is cured or there is no static mixer installed Install Disposable Static...

Страница 10: ...n you finish using the 2K Manual Dispense Valve clean the outlet manifold F and protect it from drying or crystallization as follows 1 Perform Pressure Relief Procedure page 10 2 Remove and properly d...

Страница 11: ...check valve oscillation causes ratio imbalance Install restrictors on both sides to meter a smooth flow to the manifold Sizing Restrictors If resin and hardener are at or near 1 1 ratio and viscos iti...

Страница 12: ...ion temperature range Change restrictor at mix point to balance back pressure Restriction on one side Clean mix module restrictors or check valves at mix manifold A ISO side rich lack of B RES side A...

Страница 13: ...when viewed from the rear of the gun Squarely align outlet manifold 6 to inlet manifold 1 Apply lithium grease Torque restrictors 18 to 40 50 in lb 4 5 5 6 N m Hand tighten mixer nut 7 onto outlet man...

Страница 14: ...ength of the gun from 47 in 1194 mm to 24 in 610 mm purchase two of each of the following fittings 503279 and 151243 Use these fit tings to replace fittings 4 and tubes 5 Standard Disposable Mixer Alt...

Страница 15: ...77 15E376 15E375 15E374 15E373 15E372 Restrictor Diameter and Part No Key 5000 cps 1 0 gpm 3 8 lpm 5000 cps 0 25 gpm 0 95 lpm 1000 cps 0 25 gpm 0 95 lpm 500 cps 0 25 gpm 0 95 lpm 200 cps 0 25 gpm 0 95...

Страница 16: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Отзывы: