Maintenance
3A2806A
17
Drum Feed Kit, Pump
NOTE:
See supplied pump manual for maintenance,
repair, and parts information.
Tighten pump clamps and external fasteners periodi-
cally. See pump manual.
Drum Feed Kit, Changing Top
Drums
1.
See
2.
Close ball valves on top drum outlet assembly.
3.
Place a container underneath the CAM lock fitting to
catch chemicals.
4.
Disconnect the CAM lock fitting from the system.
5.
Remove the empty drum from the rack (if applica-
ble) and place it vertically on the floor.
6.
Remove the air dryer assembly ball valve assembly
from the empty drum.
7.
Inspect and clean the threads of the full drum and
removed fitting assemblies.
8.
Apply thread sealant to threads of the removed
assemblies.
9.
Install the ball valve assembly.
10. Install dryer assembly.
NOTE:
To prevent contamination of the dessicant in the
dryer canister caused by sloshing material, it is recom-
mended that the tape is temporarily placed over the air
inlet on the dryer canister. The tape should be removed
after the drum is installed.
11. Place drum on top rack and orient it so that the air
dryer assembly is on top and outlet is on the bottom.
, page 16, as
required.
13. Connect CAM lock fittings from lower drum securely
to ball valve assembly on upper drum and lock in
place.
NOTE:
CAM levers on either side of female CAM recep-
tacle should be perpendicular to the receptacle to mate
and parallel to body to lock.
14. Open both ball valves on top drum outlet assembly
to fill bottom the drum.
See
Load fluid with feed pumps
in GMS operation
manual.
NOTICE
To prevent cross-contamination of fluid when
changing drums, complete changing one compo-
nent before changing second component.
closed_ballvalves
ti19596a