Troubleshooting
30
3A0232E
Troubleshooting
Problem
Cause
Solution
Gun does not fully
actuate when trig-
gered
Safety lock engaged
Disengage safety lock
Trigger clamp pins bent
Inspect and replace if necessary
Cutter air valve stuck
Inspect and replace if necessary
Overspray on trigger clamp pins
Clean and lubricate
Needle assembly stuck
Check and adjust needle packing tension
Hardened material in the needle/seat area
Remove needle assembly, clean and replace if
necessary
Fluid does not spray
when trigger is fully
actuated
Proportioner off or in bypass mode
Turn on proportioner and make ready to spray
Worn trigger clamp pins
Inspect and replace if necessary
Worn trigger
Inspect and replace if necessary
Loose trigger clamp assembly
Inspect and torque as per the manual
Misadjusted or missing trigger clamp set
screws
Adjust or replace set screws
Hardened material in front head (passage-
way and spray tip)
Check for blockage, clean and replace as nec-
essary
Hardened material in the needle/seat area
Remove needle assembly, clean and replace if
necessary
Resin is present with
NO catalyst
No catalyst
Check catalyst fluid level
Catalyst pump in bypass
Turn on and make ready to spray
Trigger clamp out of phase
Adjust trigger clamp, see page 18
Actuator adjustment screw missing
Replace
Trigger worn
Inspect and replace if necessary
Actuator pin worn
Inspect and replace if necessary
Trigger clamp assembly loose
Inspect and torque as per the manual
Catalyst check valve stuck closed
Inspect and replace if necessary
Hardened material in the needle/seat area
Remove needle assembly, clean and replace if
necessary
No resin catalyst
ONLY
No resin
Check material fluid level
Trigger clamp out of phase
Adjust trigger clamp, see page 18
Catalyst pump in bypass
Turn on and make ready to spray
Trigger clamp out of phase
Adjust trigger clamp, see page 18
Actuator adjustment screw missing
Replace
Trigger worn
Inspect and replace if necessary
Actuator pin worn
Inspect and replace if necessary
Trigger clamp assembly loose
Inspect and torque as per the manual
Hardened material in the needle/seat area
Remove needle assembly, clean and replace if
necessary