Warnings
4
309524V
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
SPECIAL CONDITIONS FOR SAFE USE
•
For information on the required dimensions of the flameproof joints contact the holder of this certifi-
cate (Graco Inc); Flamepath joints are not intended to be repaired.
•
Special fasteners for securing equipment covers shall have a minimum yield strength of 1,100 MPa
and be corrosion resistant and sized M8 x 1.25 x 30.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause elec-
tric shock.
•
Turn off and disconnect power at main switch before disconnecting any cables and before servicing
or installing equipment.
•
Connect only to grounded power source.
•
All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
BURN HAZARD
Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe
burns:
•
Do not touch hot fluid or equipment.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in
work area
can ignite or explode. Paint or solvent
flowing through the equipment can cause static sparking. To help prevent fire and explosion:
•
Use equipment only in well-ventilated area.
•
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static sparking).
•
Ground all equipment in the work area. See
Grounding
instructions.
•
Never spray or flush solvent at high pressure.
•
Keep work area free of debris, including solvent, rags and gasoline.
•
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•
Use only grounded hoses.
•
Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they
are anti-static or conductive.
•
Stop operation immediately
if static sparking occurs or you feel a shock
.
Do not use equipment until
you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
•
Never operate with covers removed. Do not open when energized.
•
Install conduit within 18 in (457 mm).
•
Do not install if operating temperature exceeds ignition temperature of hazardous atmosphere.