3
308918
Service
Install a fluid drain valve in the bottom of the filter bowl
(6) to relieve fluid pressure and drain the filter.
Establish a preventive maintenance schedule and
clean the filter on a regular schedule to maximize
filtering efficiency and to avoid pressure drop.
WARNING
PRESSURIZED EQUIPMENT HAZARD
Before removing, cleaning, or servicing the filter,
close the inlet and outlet ball valves and open the
fluid drain valve to relieve pressure.
Relieve the pressure. See the
Warning
above.
Support the bowl (6) with your hands while unscrewing
the four eye nuts (1) and bolts (2). Lower the bowl
away from the filter housing (3). Unscrew the seat
plate (9) to remove the filter element (5). Remove the
o-ring (4), filter element (5), and gaskets (7).
If fluid leaks between the filter housing (3) and the
bowl (6), replace the o-ring (4).
Clean the bowl and element with a compatible solvent
before the fluid dries. Do not use a wire brush or sharp
object to clean. See the
Parts
list for filter element
replacement kits.
NOTE:
Clean the filter element (5) with a small paint
brush. Blow out lodged particles with air, and inspect
for damage.
Reassemble the filter in the reverse order.
8675B
1
3
4
5
8
9
2
6
Parts
Ref.
No.
Part No.
Description
Qty.
1
114769
NUT, eye; 1/2 x 13; hot galvanized
4
2
114766
BOLT, cap, hex head;
1/2 x 2.5” (62 mm) long
4
3
116177
HOUSING, filter
1
4
116183
O-RING, filter;
PTFE
encapsulated
Viton
1
5
116179
ELEMENT KIT, filter;
60 mesh (230 micron) sst element
1
6
116176
BOWL, filter; includes drain plug and
lockring
1
8
116188
GASKET,
PTFE
2
9
116182
PLATE, seat
Filter Element Kits (sst)
Part No.
Element Size
mesh (micron)
116178
30 (540)
116179
(Standard)
60 (230)
116180
100 (140)
116181
200 (74)
Technical Data
Category
Data
Dimensions
4.375” (111 mm) Wide;
13.0” (330 mm) High
Inlet and Outlet Port Size
3/4 npt(f)
Maximum Working
Pressure
300 psi
(2.1 MPa, 21 bar)
Wetted Parts
304 and 316 Series Stain-
less Steel;
PTFE
R